Removing and installing the heater with support

Type ar · emne 83.70 · version 0110 · 2016-12-21

Gælder for: Model 639 with code H12 (Auxiliary hot-water heater)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 639

EinPAS 39 Varmesystem/ventilation/køling › 39.25 Parkeringsvarme/ekstra varmesystem › 39.25.30 varmeapparat — Serie 639

AR83.70-S-5330S

Removing and installing the heater with support

14.12.2016

Model

639

with code H12 (Auxiliary hot-water heater)

Removing and installing the heater with support

1

Fuel line

2

Coolant hoses

3

Screw

4

Bolts

5

Electrical connectors

A6

STH heater unit

M46/1

STH fuel metering pump

S83.70-4509-06

Danger !

Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.
Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

Danger !

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.

No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only.
Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Danger !

Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit

Do not operate stationary heater, auxiliary heater or engine with heater booster in closed rooms or when refueling. Allow heater unit to cool down after operation and wear protective gloves.

AS83.70-Z-0002-01A

Remove/install

1

Drain coolant


Model 639 with engine 112, 272, 642, 646, 651
with code H12 (Auxiliary hot-water heater)

AR20.00-S-1140S

2

Remove fuel line (1) from STH heater unit (A6)

Collect escaping fuel.

3

Close off the fuel line (1) with the stop plugs

Record plug

*129589009100

4

Loosen clamps on coolant hoses (2)

5

Remove coolant hoses (2) from STH heater unit (A6)

Collect coolant which flows out.

6

Unscrew bolt (3)

Bracket to floor assembly

*BA83.70-N-1005-01A

7

Loosen bolts (4); do not remove completely

Secure STH heater unit (A6) to prevent it from falling down.

Bracket to floor assembly

*BA83.70-N-1005-01A

8

Disconnect electrical connections (5)

9

Disconnect electrical connector on STH fuel metering pump (M46/1)

10

Remove STH heater unit (A6) together with the bracket

11

Install in the reverse order

Check

12

Perform test run of STH heater unit (A6) and check fuel system on STH heater unit (A6) for leaktightness

Stationary heater unit

Number

Designation

Model 636, 639

BA83.70-N-1005-01A

Bracket to floor assembly

Nm

8

Removing and installing the heater with support

129 589 00 91 00

Record plug

Henviste dokumenter