1 | Fuel line |
2 | Coolant hoses |
3 | Screw |
4 | Bolts |
5 | Electrical connectors |
A6 | STH heater unit |
M46/1 | STH fuel metering pump |
S83.70-4509-06
Danger ! | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Danger ! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Danger ! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed rooms or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
| Remove/install | ||
1 | Drain coolant |
| |
2 | Remove fuel line (1) from STH heater unit (A6) | Collect escaping fuel. | |
3 | Close off the fuel line (1) with the stop plugs | Record plug | |
4 | Loosen clamps on coolant hoses (2) | ||
5 | Remove coolant hoses (2) from STH heater unit (A6) | Collect coolant which flows out. | |
6 | Unscrew bolt (3) | Bracket to floor assembly | |
7 | Loosen bolts (4); do not remove completely | Secure STH heater unit (A6) to prevent it from falling down. | |
Bracket to floor assembly | |||
8 | Disconnect electrical connections (5) | ||
9 | Disconnect electrical connector on STH fuel metering pump (M46/1) | ||
10 | Remove STH heater unit (A6) together with the bracket | ||
11 | Install in the reverse order | ||
| Check | ||
12 | Perform test run of STH heater unit (A6) and check fuel system on STH heater unit (A6) for leaktightness |
129 589 00 91 00
Record plug
Henviste dokumenter
- ar2000s1140s
- as2000z000101a Risiko for skoldningsskader på hud og øjne pga. sprøjtende, varm kølervæske. Risiko for forgiftning ved indtagelse af kølervæske
- as4700z000101a Fare for eksplosion ved tænding, fare for forgiftning ved indånding og indtagelse af brændstof samt fare for hud- og øjenskader ved kontakt med brændstof
- as8370z000201a Fare for eksplosion på grund af brændstofdampe, fare for forgiftning ved indånding af forbrændingsgas og fare for personskade på grund af forbrændinger, under eller efter at varmesystemet har været i drift.