AR83.30-P-5520F | Remove/install expansion valve | 15.11.11 |
MODEL 208, 210
with CODE (580) Air conditioning (or Tempmatic for USA)
with CODE (581) Automatic air conditioning
P83.30-0341-06
Shown on model 210
1 Rubber grommet
2 Major assemblies compartment partition
5 Screw
6 Hexagon nut
82 Expansion valve
83 Suction line O-ring
84 Pressure line O-ring
Modification notes
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | |
| Notes on handling R134a refrigerant | All models with R134a refrigerant | |
1 | Drain air conditioning system (recycle refrigerant), evacuate, fill, inspect for leaks | When filling the air conditioning system, feed extracted quantity of compressor oil back into the refrigerant circuit. | |
2 | Remove left air inlet | Model 210 | |
3 | Remove right air inlet | Model 210 | |
4 | Remove wiper system | Model 210 | |
5 | Remove water collector | Model 210 | |
Model 208 | |||
6 | Remove rubber grommet (1) | Model 210 only | |
7 | Unscrew hexagon nut (6) | | |
8 | Pull tubing out of expansion valve | Seal openings (parts kit) | |
9 | Remove bolts (5) | | |
10 | Replace fluid reservoir | ||
11 | Install in the reverse order | Replace O-rings (83, 84) (moisten with compressor oil) | |
12 | Switch on the air conditioner and allow the engine to idle for roughly 4 minutes. | Set temperature selector wheel to blue notches, or with automatic air conditioning set to "" Blowers to max. | |
13 | Check air conditioning for proper operation | The air outlet temperature at the center air vent must not fall below 5 °C, if necessary | |
perform diagnosis according to diagnosis manual | |||
14 | Inspect the air conditioning circuit for leaks | Air conditioning system leak detector |
Air conditioning
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000401a Fremgangsmåde ved beskadiget eller utæt klimaanlæg
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar8230p6400f Af-, påmontering af viskersystem
- ar8325p1402f
- ar8325p1402k
- ar8325p1403f
- ar8325p1404f
- ar8330p6520e
- as8300z000101a Fare for eksplosion ved svejse- og loddearbejde på det lukkede klimaanlæg. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel