Shown on model 171 |
3 | Quick-release couplings |
4 | Air duct |
P54.10-2375-04
| Remove | ||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
1 | Open engine hood and move to vertical position | ||
2 | Open quick-release fasteners (3) and remove air duct (4) | ||
| Check | ||
3 | Visual inspection of battery or on-board electrical system battery for external leakage | If leakage found Replace battery or on-board electrical system battery, see: | |
| |||
Remove/install battery | |||
| |||
| |||
4.1 | Check fluid level of battery or on-board electrical system battery, add distilled water, if necessary | Battery or on-board electrical system battery without service fill level indicator. | |
4.2 | Check fluid level of battery or on-board electrical system battery | Battery or on-board electrical system battery with service fill level indicator. | |
Fluid level indicator via service fill level indicator, if color is white, the acid level is too low: Replace battery or on-board electrical system battery, see: | |||
| |||
Remove/install battery or on-board electrical system battery | |||
| |||
| |||
5 | Check battery or on-board electrical system battery | ||
Use Midtronics battery tester/test equipment for the test. | |||
Cold cranking amps as per EN | |||
Commercially available devices/tools | |||
Battery capacity 12 Ah | |||
Battery capacity 30 Ah | |||
Battery capacity 35 Ah | |||
Battery capacity 46 Ah | |||
Battery capacity 60 Ah VRLA/AGM | |||
Battery capacity 60 Ah | |||
Battery capacity 62 Ah | |||
Battery capacity 70 Ah VRLA/AGM | |||
Battery capacity 74 Ah | |||
Battery capacity 80 Ah VRLA/AGM | |||
Battery capacity 84 Ah | |||
Battery capacity 90 Ah VRLA | |||
Battery capacity 95 Ah VRLA | |||
Battery capacity 100 Ah | |||
6 | Reduce increased voltage after charging process | On a battery or an on-board electrical system battery that is disconnected from the on-board electrical system and with a "Surface voltage" message in the display of the Midtronics battery tester/test equipment. | |
After reducing increased voltage, check battery or on-board electrical system battery again. | |||
7 | Charge battery or on-board electrical system battery | With test code "Charge and check" of Midtronics battery tester/test equipment. | |
Check the battery or on-board electrical system battery again after charging. | |||
| Install | ||
8 | Install air duct (4) and close quick-release fasteners (3) | ||
9 | Close engine hood |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1002-01A | Battery capacity 30 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 90 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 540 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1003-01A | Battery capacity 35 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 100 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 520 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1005-01A | Battery capacity 46 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 140 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 420 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 190 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 480 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 265 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 680 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1016-01A | Battery capacity 100 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 300 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 760 |
Henviste dokumenter
- ah5410p000101a
- ah5410p000101a Oplysninger om batterier
- ar5410p0005v
- ar5410p0005w
- ar5410p112901a Kontrol af batteri
- ar5410p112903a Reduktion af forøget spænding efter opladning
- ar5410p1130v
- ar8840p1000v
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for