P54.10-2377-09
3 Ground cable
4 Cover for positive terminal
5 Positive line
10 Bracket
11 Supporting bracket
G1 Battery
6 Venting hose
7 Nut
8 Retaining clip
9 Nut
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Notes on battery | ||
1 | Disconnect ground line (3) from the battery (G1) | ||
2 | Remove positive terminal cover (4) | ||
3 | Disconnect positive line (5) from battery (G1) | Installation: Ensure that the positive line (5) is firmly seated, otherwise the positive terminal may be damaged. | |
4 | Pull vent hose (6) off the battery (G1) | Installation: Pay attention to routing of the vent hose (6) without kinks. | |
5 | Unscrew nut (7) and remove the retaining bracket (8) | ||
6 | Unscrew nut (9) and remove bracket (10) | ||
7 | Remove battery (G1) from the engine compartment | Use supporting bracket (11). | |
8 | Install in the reverse order | ||
9 | Perform basic programming |
Henviste dokumenter
- ah5410p000101a Oplysninger om batterier
- ah5410p000101a
- ar0019p0200v
- ar5410p0003v
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for