AR54.10-D-1129-01TS | Check battery | ||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
Reduce increased voltage after charging process | |||
| 000 588 02 19 00 Battery tester | ||
| 000 588 03 19 00 Load tester |
All test steps and entries must be conducted painstakingly.
Otherwise the test result may be incorrect.
Whenever possible, perform the tests with the battery still installed and connected.
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m). |
2 | Switch off interior and exterior lights. |
3 | Switch off audio component (e.g. radio). |
4 | Connect battery tester to battery. |
Do not connect battery tester to jump start or charging terminal point when the battery is installed; always connect it directly to the battery. |
Check that the battery test device is securely connected to the battery. |
Once the battery tester has been connected the currently measured battery voltage is displayed. |
If during the test procedure the battery test device detects so-called "system noise", |
|
check whether all consumers are switched off and wait approx. 2 min until the quiescent current is minimized and the bus systems are shut down. |
5.1 | If, with battery installed, the "Surface voltage" message is shown during the test. |
5.2 | If, with battery removed, the "Surface voltage" message is shown during the test. |
6 | Conduct test procedure according to battery test device menu navigation. |
7 | After the test print out the test code displayed and store it safely in a tamperproof manner. |
Henviste dokumenter
- ah5410p000101a Oplysninger om batterier
- ah5410p000101a
- ar5410d112903ts
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for