D54.10-1225-79
Shown on model 907 with engine 651.9 |
1 | Jump-start connection point | 4 | Ground terminal | |
2 | Cover | 5 | Ground connection | |
3 | Positive terminal |
D54.10-1226-79
Shown on model 910 with engine 651.9 |
1 | Jump-start connection point | 4 | Ground terminal | |
2 | Cover | 5 | Ground connection | |
3 | Positive terminal |
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
Preservation of on-board electrical system voltage | |||
1 | Open hood. | | |
2 | Slide back cover (2) and clip positive terminal (3) of charger onto jump-start connection point (1). | ||
| 000 588 00 81 00 Charger | ||
| |||
Observe symbols on cover (2). | |||
3 | Clip ground clamp (4) of charger onto ground connection (5). | ||
4 | Switch on charger. | ||
5 | Switch off charger after completing check and diagnosis work on the vehicle. | ||
6 | Disconnect ground clamp (4) of charger from ground connection (5). | ||
7 | Disconnect positive terminal (3) of charger from jump-start connection point (1). | ||
8 | Close hood. |
Henviste dokumenter
- ah5410p000101a Oplysninger om batterier
- ah5410p000101a
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for
- ws5400p0037b