P27.55-2381-09
1 | Transmission cooling module | 4 | Coolant hose | |
2 | Coolant hose | 5 | Guide lug | |
3 | Bolts | 6 | Oil filter cover |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Caution | Risk of injury to skin and eyes due to handling of transmission oil. Health risk caused by swallowing transmission oil | Wear protective gloves, protective clothing and safety glasses. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Topical note | Notes on self-locking nuts and bolts | ||
Notes on automatic transmission | |||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmitter range (min. 2 m). | ||
2 | Drain off coolant. | ||
Installation: Install lower engine cover only after leak test. | |||
3 | Remove air filter unit. | ||
4 | Unclip electrical wiring harness from transmission oil cooling module (1). | ||
5 | Release and remove coolant hose (4) from cooler. | ||
6 | Unscrew bolts (3). | Bolt, cooler module to transmission housing | |
7 | Remove transmission oil cooling module (1) from automatic transmission with coolant hoses (2, 4) remaining and collect escaping transmission oil with a suitable container. | ||
8 | Remove coolant hose (2) from transmission oil cooling module (1). | Hose clamp pliers | |
9 | Remove transmission oil cooling module (1) and seal openings with suitable means. | Installation: Ensure that guide lug (5) is correctly seated. | |
Installation: Replace seal. | |||
10 | Remove coolant hose (4) from transmission oil cooling module (1). | If the transmission oil cooling module (1) is replaced. | |
Hose clamp pliers | |||
11 | Unscrew oil filter cover (6) and remove oil filter element. | If the transmission oil cooling module (1) is replaced. | |
Oil filter cover to cooler module | |||
12 | Install in the reverse order. | ||
| Check | ||
13 | Check transmission oil level, and correct if necessary. | ||
14 | Check cooling system for leaks. | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
Warning | Risk of burn injuries, suffocation and poisoning when working on the exhaust system and the components connected to it. Risk of suffocation and risk of poisoning caused by inhalation of gaseous and solid components of the exhaust. Risk of poisoning caused by skin contact with solid components of the exhaust. | Wear protective clothing and safety glasses. Use the extraction system. Move people out of the hazard area. | |
15 | Perform engine test run and check transmission for proper operation and leaktightness. |
454 589 00 37 00
Hose clamp pliers
Henviste dokumenter
- ah0000n000101a Oplysninger om selvlåsende bolte og møtrikker
- ah0000p500001a Oplysninger om forebyggelse af skader på grund af snavs og fremmedlegemer
- ah2719p000101nkb Oplysninger om automatgearkasse
- ah2719p000101nkb
- ar0910p1150mfc
- ar2000p1010mfd
- ar2000p1142mfc
- ar2020p744101rq
- ar2700p0104mfc
- as0000z000501a Fare for ulykke ved automatisk igangsætning når motoren kører. Fare for personskade på grund af knusning og forbrænding, hvis der arbejdes mens motoren startes eller kører
- as0000z001701a Fare for personskade på grund af snitsår eller hudafskrabninger grundet skarpkantede køretøjsdele
- as0040z000101a Fare for personskade på hud og øjne ved håndtering af gearolie. Sundhedsfare ved indtagelse af gearolie
- as2000z000101a Risiko for skoldningsskader på hud og øjne pga. sprøjtende, varm kølervæske. Risiko for forgiftning ved indtagelse af kølervæske
- as4900z000101a Forbrændings-, kvælnings- og forgiftningsfare ved arbejde på udstødningssystemet og dermed forbundne komponenter. Kvælningsfare og fare for forgiftning ved indånding af gasformede og faste komponenter i forbrændingsgassen. Fare for