ar2000p1145slr

Venting air from the low temperature circuit

Type ar · emne 20.00 · version 0101 · 2006-07-26

Gælder for: ENGINE 155 in MODEL 199

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 20 Motorkøling › 20.00 Generelt — Serie 199

EinPAS 15 Motor › 15.25 Motorkølesystem › 15.25.5 kølervæskekredsløb komplet — Serie 199

Gælder også for motorer/gearkasser: 155 ***

AR20.00-P-1145SLR

Venting air from the low temperature circuit

28.8.03

ENGINE 155 in MODEL 199

Venting air from the low temperature circuit

P20.00-2199-09

Connection diagram

1 Vent line

4 Exhaust air line

5 Compressed-air connection

2 Connecting line of vacuum box

3 Outlet line

Venting air from the low temperature circuit

P58.30-2021-04

6 Venturi nozzle

7 Pressure tube

M Connection

U Connection

Venting air from the low temperature circuit

P20.00-2230-01

8 Maximum mark

Connecting

Danger!

Risk of injury to skin and eyes suffering scalding from contact with hot coolant spray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles.

Wear protective gloves, protective clothing and eye protection.

AS20.00-Z-0001-01A

1.1

Screw on the connection (M) at the pressure tube (7) of the venturi nozzle (6)

During first assembly of the venturi nozzle.

The venturi nozzle (6) will lose its function if used without the pressure tube (7). The venturi nozzle (6) does not generate a vacuum, but creates excess pressure at connection (U) if the compressed air is connected without the pressure tube (7).

2

Connect cooler vacuum filling device according to connection diagram

Cooler vacuum filling device

*285589002100

NTKL adapter

*285589012100

3

Close all valves on the ventilation device.

4

Prepare the low temperature circuit for the bleeding process

AR20.00-P-1145-02SLR

Notes on coolant

All engines

AH20.00-N-2080-01A

Bleeding

5

Bleed low temperature circuit with cooler vacuum filling device

AR20.00-P-1145-03SLR

Notes on coolant

All engines

AH20.00-N-2080-01A

Cooler vacuum filling device

*285589002100

6

Actuate low temperature circuit with STAR DIAGNOSIS

Actuate the left charge air cooler circulation pump (M44/1) and right charge air cooler circulation pump (M44/2) using STAR DIAGNOSIS and allow to run for

45 seconds.

STAR DIAGNOSIS diagnosis system

*WH58.30-Z-1048-13A

Disconnecting

7

Close the cooler vacuum filling device

8

Fill up fill level in the expansion reservoirs up to the maximum mark (8)

An excessively high fill level can prevent full purge of the system.

An incompletely purged system can lead to cutting out of the compressor charging due to different temperature conditions.

Venting air from the low temperature circuit
Venting air from the low temperature circuit

285 589 01 21 00

NTKL Adapter

Vacuum-type cooling system filler

285 589 00 21 00

Commercially available tools

Number

Designation

WH58.30-Z-1048-13A

STAR DIAGNOSIS diagnosis system, Compact Passenger Car

6511 1801 00

Henviste dokumenter