P09.40-2572-09
2 | Screw | 5 | Oil feed line | |
3 | Screw | 6 | Screw | |
4 | Screw |
Warning | Risk of burn injuries, suffocation and poisoning when working on the exhaust system and the components connected to it. Risk of suffocation and risk of poisoning caused by inhalation of gaseous and solid components of the exhaust. Risk of poisoning caused by skin contact with solid components of the exhaust. | Wear protective clothing and safety glasses. Use the extraction system. Move people out of the hazard area. | |
Caution | Risk of injury to skin and eyes due to handling of engine oil. Risk of poisoning caused by swallowing engine oil | Wear protective gloves, protective clothing and safety glasses. | |
Topical note | Notes on threaded connections fastened using a tightening angle-based tightening process | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove upper engine cover. | ||
Installation: Only install upper engine cover after the leak test. | |||
2 | Unscrew the bolt (2, 3, 4, 6). | Screw, oil feed line to | |
3 | Remove the oil feed line (5) and seal the openings with suitable stop plugs. | Installation: Install new sealing rings. | |
Record plug | |||
4 | Install in the reverse order. | ||
5 | Check engine oil level and correct. | ||
| |||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
6 | Carry out engine test run and check engine for proper leaktightness and leaktightness. | ||
7 | Install upper engine cover. |
129 589 00 91 00
Record plug
Henviste dokumenter
- ah0000p002001a Oplysninger om skrueforbindelser, som er fremstillet efter den drejevinkelstyrede tilspændingsmetode
- ah0000p500001a Oplysninger om forebyggelse af skader på grund af snavs og fremmedlegemer
- ap1800p1812ski Motoroliestand kontrolleres med kombiinstrument
- ar0110p2405mrt
- as0000z000501a Fare for ulykke ved automatisk igangsætning når motoren kører. Fare for personskade på grund af knusning og forbrænding, hvis der arbejdes mens motoren startes eller kører
- as1800z000101a Fare for personskade på hud og øjne ved håndtering af motorolie. Fare for forgiftning ved indtagelse af motorolie
- as4900z000101a Forbrændings-, kvælnings- og forgiftningsfare ved arbejde på udstødningssystemet og dermed forbundne komponenter. Kvælningsfare og fare for forgiftning ved indånding af gasformede og faste komponenter i forbrændingsgassen. Fare for