Funktionsgruppe 1 Motor › 09 Luftindsugning, luftladning › 09.40 Turbolader — Serie 357 · Serie 364 · Serie 372 (modeller 9**) · Serie 376 · Serie 382 · Serie 384 · Serie 386 · Serie 390 · Serie 397 · Serie 398 · Serie 427 · Serie 435 · Serie 437 · Serie 441 · Serie 443 · Serie 615 · Serie 616 · Serie 617 · Serie 619 · Serie 651 · Serie 652 · Serie 674 · Serie 675 · Serie 676 · Serie 677 · Serie 678 · Serie 679 · Serie 682 · Serie 684 · Serie 685 · Serie 693 · Serie 694 · Serie 695

EinPAS 15 Motor › 15.30 Luftindsugning/opladning › 15.30.31 Servomotor/indstillingsled/cylinder — Serie 357 · Serie 364 · Serie 372 (modeller 9**) · Serie 376 · Serie 382 · Serie 384 · Serie 386 · Serie 390 · Serie 397 · Serie 398 · Serie 427 · Serie 435 · Serie 437 · Serie 441 · Serie 443 · Serie 615 · Serie 616 · Serie 617 · Serie 619 · Serie 651 · Serie 652 · Serie 674 · Serie 675 · Serie 676 · Serie 677 · Serie 678 · Serie 679 · Serie 682 · Serie 684 · Serie 685 · Serie 693 · Serie 694 · Serie 695

Gælder også for motorer/gearkasser: 341 ***, 366 ***, 377 9**, 383 ***, 385 ***, 392 ***, 394 ***, 396 ***, 417 ***, 612 ***, 697 ***, 699 ***

AR09.40-B-5910-02A

Check control unit.

OM 366 A (372.9, 377.9), M 366 LAG (376.9)

Check control unit.
Check control unit.

124 589 15 21 00

Analyzer

000 589 75 63 00

Adapter

Check control unit.

B09.40-0016-11

Check the relief valve (1) for external damage. In case of external deformation or if adjustment has been changed, replace the complete turbocharger.

Install manual pump (2) into the intake pipe (3) of the relief valve (1) and apply 1.25 bar pressure.

Note that the maximum pressure for the test should not exceed 2 bar, since the diaphragm may be damaged.

If the relief valve membrane (1) is damaged, the pressure will exit between the valve body and the stem, at the location shown by the arrow. In this case, replace the complete turbocharger.

The relief valve test (1) to be carried out without the manual pump equipped with pressure gauge requires care and criteria to be adopted:

It may be performed using a pressure gauge with a scale up to 5 bar, however, it shall have an adjusting log regulator to control the pressure, which may not exceed 2 bar.

For this control of the turbocharger, the engine must be stopped, and the compressed air can exit from an outside line or one of the vehicle's reservoirs. The compressed air must be clean and dry.