1 | Electrical connection |
2 | Electrical connection |
N3/10 | ME-SFI [ME] control unit |
P07.08-2221-11
| Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Read out variant coding of the ME-SFI [ME] control unit (N3/10) with diagnostic system | When replacing ME-SFI [ME] control unit (N3/10) | |
| |||
Connect up diagnostic system and read data from ME-SFI [ME] control unit (N3/10) in diagnostic system. | |||
Installation: Transfer stored data to new ME-SFI [ME] control unit (N3/10). | |||
2 | Switch off ignition and remove transmitter key | ||
3 | Remove engine cover | ||
4 | Disconnect Electrical connections (1, 2) on ME-SFI [ME] control unit (N3/10) | ||
5 | Unclip ME-SFI [ME] control unit (N3/10) upwards and take it off | Installation: Ensure correct seating of the ME-SFI [ME] control unit (N3/10). | |
6 | Install in the reverse order | ||
Danger ! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
7 | Carry out an engine test run |
Henviste dokumenter
- ad0000p200004a
- ad0000p200004a
- ah5400p000101a Oplysninger med henblik på at undgå skader på elektroniske komponenter på grund af elektrostatisk afladning
- as0000z000501a Fare for ulykke ved automatisk igangsætning når motoren kører. Fare for personskade på grund af knusning og forbrænding, hvis der arbejdes mens motoren startes eller kører