AD07.52-S-6000-16A | PEC fuel injection and ignition system test of electrical system ignition output stage 2 cylinders 2 and 3 |
| Scope of test | Measuring instrument/ | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Ignition output stage 2, cylinders 2 and 3 + fails Current value not achieved Combustion period and combustion voltage Ignition coil 1 | | Engine: Idling Actual value 25 Actual value 26 |
1.7-2.3 ms 30-35 V | 1.1 Spark plugs Ignition cables Ignition coil 1 | ||
1.1 | Voltage supply Ignition coil 1 |
1 (1.1) | |
28 (2.11) | Ignition: ON | 11-14 V | Cables |
1.2 | Dwell period Ignition coil 1 |
28 (2.11) | |
10 (1.10) | Engine: Idling Test connection: Primary individual display Measuring range 40 V Time range 5 ms | 3 - 4 ms (Depends on battery voltage) | 1.3 Control module |
1.3 | Quiescent current shutoff Ignition coil 1 |
28 (2.11) | |
10 (1.10) | Ignition: ON Engine: Idling | approx. 0 V 0.3-0.5 V | Ignition coil 1 < 0.3 V cable from ignition coil 1 to control module open-circuited. > 0.5 V ignition coil 1 |
1.4 | Primary voltage of ignition coil 1 |
28 (2.11) | |
10 (1.10) | Starter: Operate Test connection: Primary individual display Measuring range 400 V Time range 100% Connect kilovolt pincers to ignition coil 1. | 200-380 V | 1.5 Control module |
1.5 | Primary winding of ignition coil 1 |
28 (2.11) | |
2 (1.2) | Ignition: OFF Coupling "2" disconnected at control module | 0,3-0,6 Ω | Ignition coil 1 |
1.6 | Ignition voltage of ignition coil 1 | Engine tester | Starter: Operate Test connection: Secondary individual display Measuring range 20 kV Time range 100% Connect kilovolt pincers to ignition coil 1 | 8-20 kV | 1.7 Spark plugs Control module | ||
1.7 | Secondary winding of ignition coil 1 | 4a | Ignition coil 1 | 4b | Ignition coil 1 removed Ignition cables disconnected at ignition coil. | 5.2-8.5 kΩ | Ignition coil 1 |