gf8340p2018a

Expansion valve, basic function

Typ gf · téma 83.40 · verze 0102 · 2020-06-24

Platí pro: Model all (CAR)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.40 Automatická klimatizace — Řada 900 (modely 9**) · Řada 902 (modely 9**) · Řada 904 (modely 918, 919, 924, 925, 938, 943, 957) · Řada 906 (modely 917, 918, 924, 953)

Platí také pro motory/převodovky: 139 ***, 254 ***, 256 ***, 272 ***, 276 ***, 282 ***, 457 9**, 541 9**, 542 9**, 608 ***, 700 4**, 700 420, 700 421, 700 422, 700 423, 715 3**, 715 5**, 722 6**, 722 9**, 724 ***, 724 0**, 724 033, 724 044, 724 045, 724 1**, 724 103, 724 114, 724 115, 724 120, 725 ***, 725 0**, 725 035, 725 037, 725 038, 725 085, 725 1**, 739 390, 739 391, 739 395, 739 396, 739 397, 739 398, 739 399, 740 698, 743 3**, 743 4**, 743 498, 746 971, 924 9**, 924 910, 925 9**, 926 9**

GF83.40-P-2018A

Expansion valve, basic function

23.06.2020

Model

all (CAR)

General

The expansion valve sprays refrigerant into the evaporator. The injection quantity depends on the pressure and the temperature of the refrigerant supplied.

Expansion valve, basic function

1

Expansion valve

P83.40-5561-82

Location

The expansion valve (1) is located at the rear of the engine compartment at the line passage to the vehicle interior.

Structure

Expansion valve, basic function

1

Expansion valve

1.1

Diaphragm

1.2

Aluminum housing

1.3

Tappet

1.4

Valve ball

1.5

Spring

P83.40-A038-73

Function

When the air conditioning system is switched on, the pressure in the evaporator decreases, causing the diaphragm in the expansion valve (1) to arch. The diaphragm motion is transmitted to a plunger (1.3). The plunger (1.3) pushes a valve ball (1.4) out of its seat, thereby opening the expansion valve (1).

The opened expansion valve (1) enables the refrigerant to be injected into the evaporator. The movement of the diaphragm (1.1) depends on both the suction pressure and the temperature at the evaporator outlet. This means that only the amount of refrigerant that can evaporate optimally is injected.