gf2010p2003a

Coolant pump switchover valve, basic function

Typ gf · téma 20.10 · verze 0104 · 2020-09-10

Platí pro: Engine 260, 608, 654, 656

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 20 Chlazení motoru › 20.10 Čerpadlo chladicí kapaliny, termostat chlazení — Řada 654 · Řada 656

Platí také pro motory/převodovky: 260 ***, 608 ***

GF20.10-P-2003A

Coolant pump switchover valve, basic function

10.09.2020

Engine

260, 608, 654, 656

Coolant pump switchover valve, basic function

P20.10-2551-79

Example illustration

1

Coolant pump switchover valve

Overview

This document contains information on:

General

Function

General

The coolant pump switchover valve controls the coolant feed to the coolant pump. It is located on the coolant pump.

Coolant pump switchover valve, basic function

Structure of the coolant pump switchover valve

1

Coolant pump switchover valve

2

Connection for the coolant pump vacuum unit

3

Ventilation connection (atmosphere)

4

Vacuum pressure supply connection

P20.10-A056-01

Function

If the coolant pump switchover valve is not actuated, it is open.

The coolant pump is cut-in in the post-start phase if one of the following conditions is met:

Max. shutoff duration of 300 s after engine start is reached.

Post-start phase limit values for intake air temperature and coolant temperature and for total injected fuel quantity stored in performance map of combustion engine control unit have been reached.

Engine speed or injection quantity exceed defined limit value.

"Heating" request for vehicle interior is carried out.