ar9160p061105a

Deployment of airbag units when no deployment device is present

Typ ar · téma 91.60 · verze 0120 · 2009-09-24

Platí pro: MODEL 163, 168, 170, 202, 203, 208, 209, 210, 215, 220, 230, 240, 414, 461, 463 Nicht für gültig'

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 91 Sedadla, lůžka, zádržný systém › 91.60 Airbag, ochrana chodců — Řada 163 · Řada 168 · Řada 170 · Řada 202 · Řada 203 · Řada 208 · Řada 209 · Řada 210 · Řada 215 · Řada 220 · Řada 230 · Řada 240 · Řada 414 · Řada 461 · Řada 463

EinPAS 27 Systémy pasivní bezpečnosti/zádržné systémy › 27.16 Airbag › 27.16.20 Airbag — Řada 163 · Řada 168 · Řada 170 · Řada 202 · Řada 203 · Řada 208 · Řada 209 · Řada 210 · Řada 215 · Řada 220 · Řada 230 · Řada 240 · Řada 414 · Řada 461 · Řada 463

AR91.60-P-0611-05A

Deployment of airbag units when no deployment device is present

Danger!

Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.

Model 163, 168, 170, 202 as of 1.7.93, 203, 208, 209, 210, 215, 220, 230, 240, 414, 461 as of 1.4.94, 463

Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply.

AS91.00-Z-0001-01A

Danger!

Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.

Model 202 up to 30.6.93

Store airbag unit with deployment face up, do not subject to temperatures above 100 °C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13).

AS91.00-Z-0001-01B

Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units

AH91.60-P-0611-02P

Ignition cable for firing airbag and seat belt tensioner units

WF58.50-P-9160-02A

Notes on disposing of airbag and emergency tensioning retractor units

OS91.00-P-0001-01A

Use of self-fabricated ignition cable

1 Fabricate ignition cable with a length of at least 10 m with pressure switch.

2 Plug the 2-pin plug connector into the corresponding airbag unit.

3 Connect ignition cable to battery.

4 Press both pressure switches at the same time.

5 For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 2 to 4 after plugging the ignition cable into the second squib.

Maintain a safe distance of 10 meters.

Odkazované dokumenty