ar8370d5744a

Remove/install combination sensor for overheating/flame

Typ ar · téma 83.70 · verze 0101 · 2003-09-29

Platí pro: MODELS 901.62#, 902.62#, 903.62#, 904.62#, 905.62# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater AIRTRONIC heater D2 MODELS 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater AIRTRONIC heater D4 MODELS WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater AIRTRONIC heater D4

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 901 (modely 62*, 66*, 67*) · Řada 902 (modely 62*, 66*, 67*) · Řada 903 (modely 62*, 66*, 67*) · Řada 904 (modely 62*, 66*) · Řada 905 (modely 62*)

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.12 Snímač/spínač/kabelový svazek — Řada 901 (modely 62*, 66*, 67*) · Řada 902 (modely 62*, 66*, 67*) · Řada 903 (modely 62*, 66*, 67*) · Řada 904 (modely 62*, 66*) · Řada 905 (modely 62*)

AR83.70-D-5744A

Remove/install combination sensor for overheating/flame

24.11.02

MODELS 901.62#, 902.62#, 903.62#, 904.62#, 905.62# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
AIRTRONIC heater D2

MODELS 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
AIRTRONIC heater D4

MODELS WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
AIRTRONIC heater D4

Remove/install combination sensor for overheating/flame

D83.70-1287-09

1 Cover

2 Casing housing

3 Locking lug

7 Auxiliary heating control unit

8 Combination sensor plug connection line

9 Combination sensor connection line

4 Locking clamp

5 Combination sensor for overheating/flame

6 Heat exchanger

Remove/Install

1

Remove heater

Models 901.6, 902.6, 903.6, 904.6, 905.6 with AIRTRONIC heater D2

AR83.70-D-5302H

Models 901.6, 902.6, 903.6, 904.6,

WD1, WD2, WD3, WD6, WD7 with AIRTRONIC heater D4

AR83.70-D-5302K

2.1

Remove heater from the housing

Models 901.6, 902.6, 903.6, 904.6,

WD1, WD2, WD3, WD6, WD7 with AIRTRONIC heater D4

AR83.70-D-5399A

3

Unlock locking lugs (3) of cover (1)

4

Lift up cover (1) and remove from casing housing (2) of the heater

5

Remove auxiliary heater control unit (7)

Only remove control unit, do not disconnect cables

AR83.70-D-5937F

6

Disconnect plug (8) of connection lines for combination sensor from auxiliary heater control unit (7)

7

Release locking clamp (4)

Installation: Route connection lines (9) of combination sensor through the hoop eye of the locking hoop (arrow).

8

Remove combination sensor (5) from heat exchanger (6)

Installation: Push combination sensor up to the stop under the casing housing. Check installation position of combination sensor. The combination sensor must make flat contact with the heat exchanger, if necessary correct the position of the sensor.

9

Install in the reverse order