AR83.70-D-5399A | Remove/install heater at housing | 22.11.02 |
MODEL 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät B3L-C compact
MODEL 901.66# /67#, 902.66# /67#, 903.66# /67#, 904.66# ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D4
MODEL WD1##, WD2##, WD3##, WD6##, WD7## ### up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D4
D83.70-1284-10
1 Heater housing
2 Connection ring
3 Firewall intake air side
4 4-pin plug housing
5 7-pin plug housing
6 Firewall warm air side
D83.70-1285-10
1 Heater housing
7 Heater unit
8 Exhaust pipe
9 Combustion air line
10 Flange gasket
| Remove/Install | ||
1 | Remove heater | ||
2 | Unlock and remove connection (2) on the intake air side | Bayonet lock. | |
3 | Detach 4-pin and 7-pin plug housing (4 ,5) from heater housing (1) | ||
4 | Detach firewall on intake air and warm air side(3, 6) | ||
5 | Detach combustion air line (9) from heater (7) and from heater housing (1) | ||
6 | Detach exhaust gas pipe (8) from heater (7) | ||
7 | Detach heater from heater housing | ||
8 | Remove flange gasket (10) from heater flange | Installation: Check condition of flange gasket (10) and replace if necessary. | |
9 | Install in the reverse order |