AR83.70-D-1178D | Check delivery rate of the fuel metering pump | 15.12.97 |
MODEL 901.3##, 902.3## /4##, 903.3## /4##, 904.3## /4## ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heizgerät D1L-C compact
MODEL 901.3## /4##, 902.3## /4##, 903.3## /4##, 904.3## /4## ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL 901.0##, 902.0##, 903.0##, 904.0## ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heizgerät B3L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6##, 905.6## ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D1L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6## ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6## ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät B3L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6##, 905.6## ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D2
MODEL 901.6##, 902.6##, 903.6##, 904.6## ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D4
MODEL WD1##, WD2##, WD3##, WD6##, WD7## ### up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D4
D83.70-1269-06
1 Fuel metering pump
2 Fuel pipe
3 Measuring hose
4 Measuring glass
5 Battery
6 Multimeter
| Remove | ||
Danger! | Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel. | No fire, sparks, naked flames or smoking. Wear protective clothing when handling fuel. | |
| Preconditions/notes regarding checking the delivery rate of the fuel metering pump | ||
1 | Remove, clean and reinstall fuel strainer in intake connection fitting of fuel metering pump | ||
2 | Detach fuel line (2) on pressure side of fuel metering pump (1) | ||
3 | Connect measuring hose (3) on the pressure side of the fuel metering pump and insert the end of the measuring hose in a measuring glass (4) | . | |
4 | Connect multimeter (6) for monitoring battery voltage with the battery (5) | There must be a battery voltage of 11 to 13 V for measuring the delivery quantity. | |
Bleeding | |||
5 | Switch heater unit on | The fuel delivery begins after approx. 45 seconds. To bleed the fuel line, leave the heater in operation until the fuel leaves the measuring hose evenly and free of bubbles. | |
6 | Switch off heater unit | ||
7 | Empty the measuring glass and insert the end of the measuring hose in the measuring glass again | ||
Measuring | |||
8 | Switch heater unit on | The fuel delivery begins after approx. 1 minute. During the measurement keep the measuring glass at the height of the heater. | |
9 | Wait for the end of the fuel delivery | The auxiliary heater control unit ends the fuel delivery after approx. 90 seconds. | |
10 | Switch off heater unit | ||
11 | Determine the delivery quantity in the measuring glass and compare with the specified values. | If the specified values are not achieved: | |
Replace fuel metering pump. | |||
| Install | ||
12 | Detach multimeter (6) from the battery (5) | ||
13 | Detach measuring hose (3) from the fuel metering pump and attach fuel line (2) again |
Test values of fuel metering pump
Number | Designation | Auxiliary hot air heater (Code H11) D1L-C compact heater | Auxiliary hot air heater (Code H11) D3L-C compact heater | Auxiliary hot air heater (Code H11) B3L-C compact heater | ||
BE83.70-N-1001-04A | Fuel delivery quantity in 90 seconds | min | cm3 | 3.4 | 4.5 | 9.5 |
max. | cm3 | 4.7 | 5.5 | 11.5 | ||
Test values of fuel metering pump
Number | Designation | Auxiliary hot air heater (code H11) AIRTRONIC D2 heater | Auxiliary hot air heater (code H11) AIRTRONIC D4 heater | ||
BE83.70-N-1001-04A | Fuel delivery quantity in 90 seconds | min | cm3 | 3.7 | 5.4 |
max. | cm3 | 4.3 | 6.3 | ||
Commercially available tools
Odkazované dokumenty
- ah8370n000201a Předpoklady/pokyny ke kontrole čerpaného množství palivového dávkovacího čerpadla
- ar8370d5652f
- ar8370d5653e
- as4700z000101a Nebezpečí výbuchu při vznícení, nebezpečí otravy při vdechnutí a požití paliva inebezpečí úrazu v důsledku přímého doteku kůže a očí s palivem