AR83.70-D-5652F | Remove/install fuel metering pump | 8.9.97 |
MODEL 901.3##, 902.3## /4##, 903.3## /4##, 904.3## /4## ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heizgerät D1L-C compact
MODEL 901.3## /4##, 902.3## /4##, 903.3## /4##, 904.3## /4## ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL 901.0##, 902.0##, 903.0##, 904.0## ## as of 753731 as of 3.11.97 with CODE (H11) Warm air auxiliary heater
Heizgerät B3L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6##, 905.6## ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D1L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6## ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6## ## up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät B3L-C compact
MODEL 901.6##, 902.6##, 903.6##, 904.6##, 905.6## ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D2
MODEL 901.6##, 902.6##, 903.6##, 904.6## ## as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D4
MODEL WD1##, WD2##, WD3##, WD6##, WD7## ### up to 382001 up to 11.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät D3L-C compact
MODEL WD1##, WD2##, WD3##, WD6##, WD7## ### as of 382002 as of 12.3.02 with CODE (H11) Warm air auxiliary heater
Heizgerät AIRTRONIC D4
D83.70-1273-06
1 Plug-in wiring plug connection
2 Fuel metering pump
3 Hose clamp
4 Tank fuel line
5 Hose clamp
6 Heater unit fuel line
7 Nut
| Remove/Install | ||
Danger! | Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel. | No fire, sparks, naked flames or smoking. Wear protective clothing when handling fuel. | |
1 | Slacken hose clamp (3) and detach fuel line to tank (4) | Collect fuel which flows out. | |
2 | Slacken hose clamp (5) and detach fuel line to heater (6) | Collect fuel which flows out. | |
3 | Disconnect electrical connector (1). | ||
4 | Unscrew nut (7) and remove fuel metering pump (2) | ||
5 | Install in the reverse order |
Odkazované dokumenty
- as4700z000101a Nebezpečí výbuchu při vznícení, nebezpečí otravy při vdechnutí a požití paliva inebezpečí úrazu v důsledku přímého doteku kůže a očí s palivem