ar8330m1760d

Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks

Typ ar · téma 83.30 · verze 0102 · 2019-05-14

Platí pro: Model 905.613 Minibus Sprinter Classic 2+2 - 6.34 t, with roof-mounted air conditioning system, Hispacold 5 D

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.30 Klimatizace — Řada 905 (modely 613)

EinPAS 39 Topení/větrání/chlazení › 39.15 Klimatizace › 39.15.5 Klimatizace kompletní — Řada 905 (modely 613)

AR83.30-M-1760D

Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks

29.04.2019

Model

905.613

Minibus Sprinter Classic 2+2 - 6.34 t, with roof-mounted air conditioning system, Hispacold 5 D

Drain, evacuate and recharge air conditioning, check for proper operation and   
	check for leaks

1

Test and filling valve on low-pressure side

2

Test and filling valve on high-pressure side

M83.50-0044-11

Draining

Danger

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

1

Unscrew protective caps from test and filling valve for low-pressure side (1) and from test and filling valve for high-pressure side (2)

2

Connect suction and charging equipment

See operator's manual from device manufacturer.

3

Drain air conditioning system

See operator's manual from device manufacturer.

4

Drain separated compressor oil from the suction and charging equipment and measure the exact quantity

See operator's manual from device manufacturer.

Evacuate

5

Clean and evacuate air conditioning system

See operator's manual from device manufacturer.

Filling

6

Add compressor oil

Before filling with refrigerant, replace the drained compressor oil with new compressor oil. The specified total filling capacity may not be exceeded.

Total compressor oil filling capacity of air conditioning system (including AC compressor)

*BF83.30-N-1002-01G

7

Switch air conditioning system into Service mode

See operator's manual for air conditioning system manufacturer.

8

Fill air conditioning system

See operator's manual from device manufacturer.

Total filling capacity, refrigerant

*BF83.30-N-1001-01G

Check

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

9

Check air conditioning for proper operation

Run engine at idle speed for about 5 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system.

10

Check air conditioning system for leaks with leak detector

As refrigerant is heavier than air, the test with the probe of the leak detector must always be performed below the suspected leakage point.

Air conditioning

Number

Designation

MODEL 905.613 with Hispacold roof air conditioningD5

Model 905.613 with air conditioning system SC3-11 with additional condenser

BF83.30-N-1001-01G

Total filling capacity, refrigerant

kg

4,3

2,5

Specifications for Operating Fluids, Sheet

BB00.40-P-0361-00A

BB00.40-P-0361-00A

Air conditioning

Number

Designation

Model 905.613 with roof air conditioning system Sütrak AC 111

BF83.30-N-1001-01G

Total filling capacity, refrigerant

kg

5,5

Specifications for Operating Fluids, Sheet

BB00.40-P-0361-00A

Air conditioning

Number

Designation

MODEL 905.613 with Hispacold roof air conditioningD5

Model 905.613 with air conditioning system SC3-11 with additional condenser

BF83.30-N-1002-01G

Total compressor oil filling capacity of air conditioning system (including AC compressor)

cm3

460

250

Specifications for Operating Fluids, Sheet

BB00.40-P-0362-00A

BB00.40-P-0362-00A

Air conditioning

Number

Designation

Model 905.613 with roof air conditioning system Sütrak AC 111

BF83.30-N-1002-01G

Total compressor oil filling capacity of air conditioning system (including AC compressor)

cm3

550

Specifications for Operating Fluids, Sheet

BB00.40-P-0362-00A

Odkazované dokumenty