1 | Negative terminal |
G1 | On-board electrical system battery |
P54.10-4035-04
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
Disconnect, connect | |||
1 | Detach high-voltage charging cable on both sides | Model 453.09/39/49 | |
2 | Switch off ignition and remove key from ignition lock | | |
3 | Disconnect vehicle diagnosis system | If diagnostic system is connected. | |
4 | Close doors | Wait until the daytime running lamps have gone out. | |
5 | Open maintenance flap | ||
6 | Loosen negative terminal (1) and remove from on-board electrical system battery (G1) | Nut, battery cable to negative terminal/positive terminal of on-board electrical system battery | |
7 | Connect in the reverse order | ||
8 | Reset clock | See Owner's Manual. |
Odkazované dokumenty
- ah5410p000101a Upozornění k akumulátoru
- ah5410p000101a
- as5410z000101a Nebezpečí požáru/exploze kvůli zkratu a unikajícímu výbušnému plynu. Nebezpečí popálení/poranění poleptáním očí, pokožky a sliznic elektrolytem / elektrolytovou mlhou akumulátoru při zkratu nebo následkem světelné