ar5410p0003sr

Disconnect/connect battery ground line

Typ ar · téma 54.10 · verze 0201 · 2019-11-19

Platí pro: Model 453

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.10 Akumulátor, zdroj napětí, měnič napětí — Řada 453

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.12 Snímač/spínač/kabelový svazek — Řada 453

AR54.10-P-0003SR

Disconnect/connect battery ground line

18.11.2019

Model

453

Modification notes

25.04.2017

Disconnect diagnostic system, added.

Operation step 2

Disconnect/connect battery ground line

1

Negative terminal

G1

On-board electrical system battery

P54.10-4035-04

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

Disconnect, connect

1

Detach high-voltage charging cable on both sides

Model 453.09/39/49
If high-voltage charging cable is connected.

2

Switch off ignition and remove key from ignition lock


All electrical consumers must be switched off.
They may otherwise be damaged when the negative terminal (1) is disconnected/connected.

3

Disconnect vehicle diagnosis system

If diagnostic system is connected.

4

Close doors

Wait until the daytime running lamps have gone out.

5

Open maintenance flap

6

Loosen negative terminal (1) and remove from on-board electrical system battery (G1)

Nut, battery cable to negative terminal/positive terminal of on-board electrical system battery

*BA54.10-P-1007-01I

7

Connect in the reverse order

8

Reset clock

See Owner's Manual.

Battery

Number

Designation

Model 453

BA54.10-P-1007-01I

Nut, battery cable to negative terminal/positive terminal of on-board electrical system battery

Nm

8

Odkazované dokumenty