P15.10-2155-08
1 | Cable tie | T1/1 | Cylinder 1 ignition coil | T1/5 | Cylinder 5 ignition coil | ||
2 | Electrical connector | T1/2 | Cylinder 2 ignition coil | T1/6 | Cylinder 6 ignition coil | ||
3 | Screw | T1/3 | Cylinder 3 ignition coil | T1/7 | Cylinder 7 ignition coil | ||
4 | Spark plug connector | T1/4 | Cylinder 4 ignition coil | T1/8 | Cylinder 8 ignition coil |
| Remove/install | ||
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on avoiding damage to ignition system | ||
1 | Turn key in ignition lock to position "0" | ||
2 | Open engine hood and raise to vertical position | ||
3 | Remove air filter housing |
| |
MODEL 219.376 | |||
4 | Release electrical feed lines of the cylinder 1 ignition coil to cylinder 8 ignition coil (T1/1-T1/8) from the ignition coils | Installation: Replace cable ties (1). | |
5 | Unlock Electrical connections (2) for cylinder 1 ignition coil to cylinder 8 ignition coil (T1/1-T1/8) and detach | ||
6 | Remove bolt (3) | Screw/bolt, ignition coil to cylinder head cover | |
7 | Remove cylinder 1 ignition coil to cylinder 8 ignition coil (T1/1-T1/8) and pry off spark plug connector (4) over the cylinder head covers of the spark plugs using a double open-end wrench | Installation: Observe the assignment markings "a" and "b" applied to the ignition coils and cylinder head covers when plugging in the spark plug connectors. | |
Double open-ended wrench | |||
8 | Install in the reverse order |
110 589 01 01 00
Double open-ended wrench
Odkazované dokumenty
- ah1510p000201d Upozornění k zamezení poškozením zapalovacího systému
- ah5400p000101a Upozornění k zamezení poškozením elektronických součástí elektrostatickým výbojem
- ar0910p1150ty Demontáž, montáž skříně vzduchového filtru
- ar0910p1150tz Demontáž, montáž skříně vzduchového filtru
- ar8840p1000tx
- as0000z000201a Nebezpečí poranění kůže nebo očí při zacházení s horkými nebo žhavými předměty
- as0000z003501a Nebezpečí ohrožení života při pracích na součástech a systémech se střídavým napětím U >= 30 V (AC), resp. se stejnosměrným napětím U >= 60 V (DC)