ar1440b2031b

Flush out metering device of exhaust aftertreatment system

Typ ar · téma 14.40 · verze 0300 · 2016-02-12

Platí pro: Cumbustion engine 457.9 with Vehicle 382.15# #D, 634.0## #D with CODE MS5 (BlueTec 5)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 14 Sběrné výfukové potrubí, motorová brzda, zařízení pro snížení obsahu škodlivin ve výfukových plynech › 14.40 Dodatečná úprava spalin, AdBlue — Řada 382 (modely 15*) · Řada 634 (modely 0**)

EinPAS 15 Motor › 15.40 Výfuková soustava/dodatečná úprava výfukových plynů › 15.40.51 Čerpadlo/dávkovací jednotka/tryska — Řada 382 (modely 15*) · Řada 634 (modely 0**)

Platí také pro motory/převodovky: 457 9**

AR14.40-B-2031B

Flush out metering device of exhaust aftertreatment system

12.02.16

Cumbustion engine 457.9 with Vehicle 382.15# #D, 634.0## #D with CODE MS5 (BlueTec 5)

Flush out metering device of exhaust aftertreatment system

W14.40-1382-06

1 Metering unit

2 Compressed air pistol

3 Rinsing hose

4 Testing connection.

A Water column (4 cm)

Flush out metering device of exhaust aftertreatment system

B14.40-0027-12

1 Metering unit

5 Syringe

6 Orifice of the SCR pressure sensor - compressed air

7 Compressed air pressure sensor (17B06)

Rinsing

Danger!

Risk of burns and scalding while working on AdBlue pipes and components connected to them. Risk of injury on skin and eyes at contact with AdBlue. Risk of poisoning from swallowing AdBlue

Only catch AdBlue in appropriate containers. Only start working on the exhaust gas after-treatment system after relieving the pressure.

AS14.40-B-0001-01A

Indications for applications, material properties and handling AdBlue

AH14.40-B-0001-01A

1

Switch-off the ignition

2

Open the engine access cover

3

Connect the STAR DIAGNOSIS

4

Install the testing connection (4) in the compressed air inlet of the dosage unit (1)

Only if a testing connection (4) is not yet installed.

The test connection (4) can remain in the vehicle.

AR14.40-B-2042B

5

Remove the compressed air pressure sensor (7)

6

Fill the orifice (6) with water

Fill water, until overflowing the orifice (6).

7

Install the compressed air pressure sensor (7)

*BA14.40-B-1008-02C

8

Install the rinse hose (3) in the testing connection (4)

A measuring hose can be used as rinse hose (3).

Connect the rinse hose (3) only after finishing the flow process of the SCR system (about 5 min.).

*360589002103

9

Remove the tire valve at the rinsing hose (3)

10

Add water to the rinsing hose (3) until forming a 4 cm water column (A)

Hold the rinsing hose (3) upwards, so the water flows in direction of the testing connection (4).

11

Install the tire valve in the rinsing hose (3)

12

Connect the compressed air pistol (2) to the rinsing hose (3)

13

Rinse the metering unit (1)

To do so, actuate the rinsing hose (3) with compressed air until the water is completely eliminated.

The pressure has to be adjusted to 5.5 bar, as a too high pressure can damage the dosage unit (1).

Danger!

Risk of accidents due to vehicle unintentional move when the engine is started. Risk of injury by pinching and burn by contact during the starting procedure or with the engine running

Assure vehicle against unintentional move. Use tight fitting and closed work clothes. Do not touch heated or running parts.

AS00.00-B-0005-01A

14

Start the engine

15

Check the compressed air pressure in the dosage unit (1) with the STAR DIAGNOSIS

The actual value 69 has to be requested through the STAR DIAGNOSIS.

If the value is above the tolerance area indicated on the STAR DIAGNOSIS, the rinsing procedure has to be repeated. Should the value, after this, still not be correct:

Replace the metering unit (1)

AR14.40-B-2002B

16

Remove the rinsing hose (3)

The testing connection (4) can remain on the vehicle after testing.

17

Disconnect the STAR DIAGNOSIS

18

Close the engine access cover

Exhaust aftertreatment

Número

Denominação

Engine 457.9 with Code MS5

BA14.40-B-1008-02C

AdBlue compressed air pressure sensor SCR on dosage unit

Nm

30

Flush out metering device of exhaust aftertreatment system

360 589 00 21 03

Measuring hose