1 | Injection nozzle |
2 | Test equipment |
3 | Valve |
A | Spray pattern closed = good |
B | Spray pattern stringy = bad |
D07.10-0004-06
| Remove/install | ||
1 | Remove injection nozzles | ||
Danger ! | Risk of explosion caused by test oil being ignited. Risk of injury to skin and eyes caused by test oil streaming out | Keep all ignition sources out of the hazard area. Only check injection nozzles in the nozzle testing device. Do not touch the injection nozzle stream. | |
2 | Connect injection nozzle (1) to test equipment (2). | ||
3 | Close valve (3) and pump through injection nozzle (1) on the test equipment (2) 5 times forcefully. | ||
| Check | ||
4 | Check spray pattern and chatter of injection nozzle | ||
Tester | |||
If the spray pattern is broadly scattered, too wide and stringy (B) | |||
| |||
Repair injection nozzle (1) | |||
5 | Check ejection pressure of injection nozzle (1) | ||
The difference in the ejection pressure of the injection nozzles on an engine must not exceed 5 bar. | |||
Injection nozzles/ejection pressure | |||
Pressure difference of injection nozzles within engine max. | |||
If the specified values are not reached | |||
| |||
Repair injection nozzles | |||
6 | Install in the reverse order |