AD83.70-W-6000-45A | AHE test of electrical system combustion air blower open circuit |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Combustion air blower –//– Actuation of combustion air blower |
A3 A4 | Z14 Z14 |
B4 B8 | Ignition: OFF Heater unit: OFF (Run-on phase must have ended). Disconnect plug connections A and B on control unit (behind timer). Connect short-circuit bridge on plugs A and B on control unit. Heater unit: ON | Combustion air blower runs audibly: Loose contract: Re-connect plug connections on control unit, erase fault memory and switch on heater unit. Then tap / shake plug connections, observing HHT display. Fault cause is located at the point where fault code re-appears. 1.1 Combustion air blower not audible (not running): 1.2 | |
1.1 | Combustion air blower –//– Supply voltage Control unit (Z14) |
B4 | Z14 |
A4 | Ignition: OFF Heater unit: OFF Disconnect plug connections A and B on control unit (behind timer). Ignition: ON Heater unit: ON Carry out measurement at plugs A and B on control unit. | Value > 20 V: + | |
1.2 | Combustion air blower –//– Control unit (Z14) |
A3 | Z14 |
A4 | Ignition: OFF Heater unit: OFF Connect short-circuit bridge to plug connection A from control unit (behind timer). Ignition: ON Heater unit: ON | If fault code appears: 1.3 If fault code re-appears: Replace control unit (Z14) on trial. | |
1.3 | Combustion air blower –//– Cable harness |
14/2 | FF8 |
14/5 | Ignition: OFF Heater unit: OFF Remove cover under electrical compartment. Connect short-circuit bridge to plug connection FF8 under electrical compartment. Ignition: ON Heater unit: ON | If fault code appears: 1.4 If fault code re-appears: Plug connection / cable –//– Inspect cable harness from control unit to electrical compartment, fit new cable if necessary (use 1.5 mm 2, lilac/brown). | |
1.4 | Combustion air blower –//– Cable harness |
14/2 | G |
14/5 | Ignition: OFF Heater unit: OFF Remove short-circuit bridge on plug connection FF8 and on plug connection G (on vehicle blower). Ignition: ON Heater unit: ON | If fault code appears: 1.5 If fault code re-appears: Plug connection / cable –//– Inspect cable harness from air recirculation box to electrical compartment. | |
1.5 | Combustion air blower –//– Cable harness to heater unit |
a | X6 |
b | Ignition: OFF Switch off heater unit and remove (take care not to disconnect coolant circulation), if necessary refer to Danger! Risk of injury and of scalding with high coolant temperature! Disconnect plug connection on heater unit. Connect short-circuit bridge to plug connection G. Carry out measurement at both pins of X6 | Value < 5 Ω: Inspect plug X6 for corrosion. Replace combustion air blower complete with cable and plug X6 if necessary. Value > 10 kΩ: Inspect plug connection X6. Replace cable harness from air recirculation box to heater unit (complete with molded connection plate on heater unit) if necessary. | |