AD83.70-W-6000-37A | AHE test of electrical system flame monitor open circuit |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Flame monitor –//– Supply cable / Internal resistance |
E2 | Z14 |
E4 | Ignition: OFF Heater unit: OFF Run-on phase must have ended. Disconnect plug connection E on control unit (behind timer). Carry out measurement at connection plug E. | 2.53.5 Ω (at approx. | Value in order: 1.1 Value > 30 kΩ: Plug connection / cable –//– 1.4 |
1.1 | Flame monitor –//– Supply cable |
E2 | Z14 |
E4 | Ignition: OFF Heater unit: OFF Re-connect plug connection E on control unit (Z14). Connect volt meter to plug connection E. Ignition: ON Heater unit: ON Maintain measured value (up to max. 90s after switching on heater unit). | 150300 mV | Value > 300 mV: 1.2 Value in order: Possible loose contact: Erase fault memory and tap / shake plug connections. Cause of fault is located in area where fault code re-appears. If no fault can be determined, replace control unit (Z14) on trial. |
1.2 | Flame monitor –//– Control unit |
E2 | Z14 |
E4 | Ignition: ON Heater unit: ON Connect voltmeter to plug connection E. Heater unit: OFF | Value > 300 mV: 1.3 Value < 100 mV: Replace control unit (Z14) on trial. | |
1.3 | Flame monitor –//– Interfering voltage Flame monitor circuit |
E2 | Z14 |
E4 | Ignition: ON Connect voltmeter to plug connection E. Ignition: OFF | Value > 300 mV: Replace control unit (Z14) on trial, if voltage on voltmeter falls to approx. Cable (measured value 22.5-29.5V remains, short-circuit or cable-short to terminal 30) Value < 100 mV: Cable (short-circuit or cable-short to terminal 15) | |
1.4 | Flame monitor –//– Supply cable |
14/8 | FF8 |
14/9 | Ignition: OFF Re-connect plug connection E on control unit. Connect short-circuit bridge to plug connection FF8 under electrical compartment. Ignition: ON Heater unit: ON | If fault code appears: 1.5 If fault code re-appears: Plug connection / cable –//– Inspect cables in cable harness from control unit (Z14) to electrical compartment, fit new cable if necessary (use 1 mm2, green/yellow). | |
1.5 | Flame monitor –//– Supply cable |
14/8 | G |
14/9 | Ignition: OFF Connect short-circuit bridge to plug connection G under air recirculation box. Ignition: ON Heater unit: ON | If fault code appears: 1.6 If fault code re-appears: Plug connection / cable –//– Inspect cables in cable harness from air recirculation box to electrical compartment, fit new cable if necessary (use 1 mm2, green/yellow). | |
1.6 | Flame monitor –//– Internal resistance |
a | X8 |
b | Ignition: OFF Tip cab and remove heater unit (take care not to disconnect coolant circulation), if necessary refer to Danger! Risk of injury and of scalding with high coolant temperature! Disconnect plug connection on heater unit. Carry out measurement directly on plug X8 | Value 2.53.5 Ω: Inspect plug connections, replace cable harness from air recirculation box to heater unit complete with molded connection plate on heater unit if necessary. Value > 20 Ω: Inspect plug X8 (corrosion), replace flame monitor complete with cable and plug X8 if necessary. | |