Auxiliary heater (AHE) test of electrical system flame monitor

Typ ad · téma 83.70 · verze 0100 · 2003-06-16

Platí pro: MODEL 625.1 /2, 655, 656, 657, 658, 659 with CODE (H27) Hot water auxiliary heater DW 80 MODEL 650, 651, 652, 653, 654 with CODE (H27) Hot water auxiliary heater DW 80

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 625 (modely 1**, 2**) · Řada 650 · Řada 651 · Řada 652 · Řada 653 · Řada 654 · Řada 655 · Řada 656 · Řada 657 · Řada 658 · Řada 659

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.1 Základní informace — Řada 625 (modely 1**, 2**) · Řada 650 · Řada 651 · Řada 652 · Řada 653 · Řada 654 · Řada 655 · Řada 656 · Řada 657 · Řada 658 · Řada 659

AD83.70-W-6000-13A

Auxiliary heater (AHE) test of electrical system flame monitor

Scope of test

Measuring instrument/

Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

Flame monitor (flame monitor constantly hot)

Flame monitor in operation

Ignition: ON

Test HHT actual value 01 and 02

AD83.70-W-3006A

Switch off "engine preheating" flip switch and vehicle blower if necessary.

Heater unit: ON

Switch off heater unit after a stand-by cycle (full load up to approx. 80 °C; partial load up to approx. 90 °C; stand-by to approx. 75 °C and partial load).

Test actual value 02 after switching on, at the start of stand-by and after switching off heater unit if necessary.

Actual value 02 is "bright" immediately after heater unit switched on:

1.2

Actual value 02 is only briefly "bright" at start of stand-by or during run-on, incomplete combustion:

Check CO2 value at 24V (9.5-12 vol.-%).

Exhaust value cannot be adjusted.

Inspect intake pipe (kinked, closed).

Inspect exhaust pipe (sooted, closed).

Measure delivery quantity of fuel metering pump and replace if tolerance of fuel metering pump (M16) deviates.

Actuate combustion air blower on trial (replace if motor bearing makes loud noise).

Actual value 02 remains "bright" during stand-by or run-on:

1.1

1.1

Flame monitor

(flame monitor constantly hot)

Supply cable, internal resistance from flame monitor

E2

Z14

E4

Ignition: OFF

Heater unit: OFF

Allow vehicle engine and heater unit to cool down.

Disconnect plug connection E on control unit.

Carry out measurement at plug.

Value 715 Ω

(at approx. 25 °C)

1.2

Value 24 Ω
(at approx. 25 °C):

Replace control unit (Z14) on trial.

1.2

Flame monitor

(flame monitor constantly hot)

Internal resistance

a

X8

b

Ignition: OFF

Remove heater unit

(take care not to disconnect coolant circulation), if necessary refer to

AD83.70-W-2000-16A

Danger!

Risk of injury and of scalding with high coolant temperature!

AS83.70-Z-0002-01A

AS20.00-Z-0001-01A

Disconnect plug connection on heater unit.

Carry out measurement directly on plug connection X8

AD83.70-W-2000-18A

Value 24 Ω
(at approx.
25 °C):

Inspect plug connections under electrical compartment and in air recirculation box (on vehicle blower) (transition resistance possibly too high due to corrosion, voltage drop outside control unit).

Replace control unit (Z14) on trial, if no fault can be determined.

Value 715 Ω

(at approx. 25 °C):

Replace flame monitor complete with connection cable and plug X8 on trial.