SM54.21-W-5116A | Parameters for specified engine torque value signal | 22.8.08 |
MODEL all
with parameterizable special module (PSM), diagnosis version 1 and 2
Explanation of abbreviations:
Y = Yes
N = No
P = Set parameters
Pemerg = Parameterization for emergency operation
Nm = Entry in Newton meters
FCAN = Vehicle CAN bus
Perform if conditions on left side are satisfied
Y/N
Specified engine torque value (FCAN)
Specified engine torque value signal
(weighted accelerator pedal) (X1.9)
P
P
Pemerg
P
P
Specified engine torque value signal - Input conditions
Parameter | Connector pin at PSM / output via FCAN | Data record in as-delivered state | Data record for concrete mixer | Comments |
Specified engine torque value | FCAN |
5000 Nm |
5000 Nm | PWM maximum value Range: -5000 to + 5000 Nm Resolution: 0.2 Nm As-delivered state: |
|
-5000 Nm |
-5000 Nm | PWM minimum value Range: -5000 to + 5000 Nm Resolution: 0.2 Nm As-delivered state: | ||
|
200 |
200 | Maximum duty cycle x255 Range: 32 - 224, resolution: 1 As-delivered state: | ||
|
40 |
40 | Minimum duty cycle x255 Range: 32 - 224, resolution: 1 As-delivered state: | ||
|
0 Nm |
0 Nm | Specified engine torque value for emergency operation: Range: 0 - 5000 Nm As-delivered state: If the specified engine torque value is not available, the PSM control unit switches to a previously parameterized specified engine torque value (emergency operation). The difference between the parameterized values for duty cycle min. and max. must be > 128/255. |
Specified engine torque value signal - Function execution
Parameter | Connector pin at PSM / output via FCAN | Data record in as-delivered state | Data record for concrete mixer | Comments |
Specified engine torque value signal (weighted accelerator pedal) | X1.9 | NO | NO |