Battery/power supply test and adjustment values |
Number | Designation | MODEL 437.420/421/425/426/430/431/435/436/465/467 | MODEL 405.210/230 | |||
BE54.10-N-1001-01D | Battery test at 20 °C | Acid density (battery charged) | kg/dm3 | 1,28 | 1,28 | |
Acid density during status test | kg/dm3 | 1,26 | 1,26 | |||
Acid density during status test (tropics) | kg/dm3 | 1,21 | 1,21 | |||
Permissible deviation of individual cells | kg/dm3 | 0,04 | 0,04 | |||
BE54.10-N-1002-01D | Cold cranking amps as per DIN | A | | | ||
BE54.10-N-1003-01D | Battery capacity 96 Ah | Cold cranking amps | As per EN | A | | 680 |
BE54.10-N-1004-01D | Battery capacity 66 Ah | Cold cranking amps | As per DIN | A | 300 | |
As per EN | A | 510 | | |||
BE54.10-N-1005-01D | Battery capacity 100 Ah | Cold cranking amps | As per EN | A | | |
BE54.10-N-1006-01D | Battery capacity 115 Ah | Cold cranking amps | As per DIN | A | | |
As per EN | A | | | |||
BE54.10-N-1007-01D | Battery capacity 125 Ah | Cold cranking amps | As per DIN | A | 550 | |
As per EN | A | 900 | | |||
BE54.10-N-1008-01D | Battery capacity 135 Ah | Cold cranking amps | As per DIN | A | | |
As per EN | A | | | |||
BE54.10-N-1009-01D | Battery capacity 140 Ah | Cold cranking amps | As per EN | A | | |
BE54.10-N-1010-01D | Battery capacity 170 Ah | Cold cranking amps | As per DIN | A | | |
As per EN | A | | |
Battery/power supply test and adjustment values |
Number | Designation | MODEL 437.427/437 | MODEL 405.050/100/101/102/103/120/121/122/123/200/201/220/221 | |||
BE54.10-N-1001-01D | Battery test at 20 °C | Acid density (battery charged) | kg/dm3 | 1,28 | 1,28 | |
Acid density during status test | kg/dm3 | 1,26 | 1,26 | |||
Acid density during status test (tropics) | kg/dm3 | 1,21 | 1,21 | |||
Permissible deviation of individual cells | kg/dm3 | 0,04 | 0,04 | |||
BE54.10-N-1002-01D | Cold cranking amps as per DIN | A | | | ||
BE54.10-N-1003-01D | Battery capacity 96 Ah | Cold cranking amps | As per EN | A | | |
BE54.10-N-1004-01D | Battery capacity 66 Ah | Cold cranking amps | As per DIN | A | | |
As per EN | A | | | |||
BE54.10-N-1005-01D | Battery capacity 100 Ah | Cold cranking amps | As per EN | A | 760 | |
BE54.10-N-1006-01D | Battery capacity 115 Ah | Cold cranking amps | As per DIN | A | | 380 |
As per EN | A | | 640 | |||
BE54.10-N-1007-01D | Battery capacity 125 Ah | Cold cranking amps | As per DIN | A | | |
As per EN | A | | | |||
BE54.10-N-1008-01D | Battery capacity 135 Ah | Cold cranking amps | As per DIN | A | | 420 |
As per EN | A | | 680 | |||
BE54.10-N-1009-01D | Battery capacity 140 Ah | Cold cranking amps | As per EN | A | | |
BE54.10-N-1010-01D | Battery capacity 170 Ah | Cold cranking amps | As per DIN | A | 420 | |
As per EN | A | 680 | |
Battery/power supply test and adjustment values |
Number | Designation | MODEL 405.09/104/105/110/125/202/222 | |||
BE54.10-N-1001-01D | Battery test at 20 °C | Acid density (battery charged) | kg/dm3 | 1,28 | |
Acid density during status test | kg/dm3 | 1,26 | |||
Acid density during status test (tropics) | kg/dm3 | 1,21 | |||
Permissible deviation of individual cells | kg/dm3 | 0,04 | |||
BE54.10-N-1002-01D | Cold cranking amps as per DIN | A | | ||
BE54.10-N-1003-01D | Battery capacity 96 Ah | Cold cranking amps | As per EN | A | |
BE54.10-N-1004-01D | Battery capacity 66 Ah | Cold cranking amps | As per DIN | A | |
As per EN | A | | |||
BE54.10-N-1005-01D | Battery capacity 100 Ah | Cold cranking amps | As per EN | A | |
BE54.10-N-1006-01D | Battery capacity 115 Ah | Cold cranking amps | As per DIN | A | |
As per EN | A | | |||
BE54.10-N-1007-01D | Battery capacity 125 Ah | Cold cranking amps | As per DIN | A | |
As per EN | A | | |||
BE54.10-N-1008-01D | Battery capacity 135 Ah | Cold cranking amps | As per DIN | A | |
As per EN | A | ||||
BE54.10-N-1009-01D | Battery capacity 140 Ah | Cold cranking amps | As per EN | A | 800 |
BE54.10-N-1010-01D | Battery capacity 170 Ah | Cold cranking amps | As per DIN | A | |
As per EN | A | |