Model | 405.050/100/101/102/103/120/121/122/123/200/201/220/221 |
Model | 405.090/104/105/110/125/202/222 ## up to 253218 |
Model | 437.420/421/425/426/430/431/435/436 ## up to 262508 |
except code B89 (Low-pressure braking system) | |
Model | 437.427/437 |
except code B89 (Low-pressure braking system) | |
Model | 437.465/467 |
except code B89 (Low-pressure braking system) |
Test and adjustment values for service brake |
Number | Designation | Model 405.050/100/101/102/103/120/121/122/123/200/201/220/221 | Model 405.090/104/105/110/125/202/222 up to 253218 | |
BE42.10-N-1001-10E | Pressure regulator shutoff pressure | bar | 17,8...18,8 | 17,8...18,8 |
BE42.10-N-1002-10E | Pressure regulator cut-in pressure | bar | 15,8 | 15,8 |
BE42.10-N-1003-10E | Time from pressure regulator cutting out until regeneration compressed-air reservoir has completely emptied | s | 20 | 20 |
BE42.10-N-1004-10E | Pneumatic pressure of service brake | bar | 8,3 | 8,3 |
BE42.10-N-1005-10E | Permissible pressure loss for operation of service brake with 3.5 bar (measuring period 3 minutes) | bar | 0,4 | 0,4 |
BE42.10-N-1006-10E | Operating pressure for service brake on rear axle (circuit 1) and front axle (circuit 2) | bar | 15,8...18,8 | 15,8...18,8 |
BE42.10-N-1007-10E | Operating pressure for trailer control, parking brake (circuit 3) | bar | 8,1...8,3 | 8,1...8,3 |
BE42.10-N-1008-10E | Operating pressure for transmission control, clutch operation (circuit 4) | bar | 8,1...8,3 | 8,1...8,3 |
BE42.10-N-1009-10E | Brake pressure at coupling head for brake with parking brake engaged | bar | 6,5...8,5 | 6,5...8,5 |
BE42.10-N-1010-10E | Brake pressure at coupling head for brake with parking brake in check position | bar | 0 | 0 |
BE42.10-N-1011-10E | Operating pressure at coupling head for compressed-air supply with burst compressed-air line of coupling head for brake | bar | - | 1,5 |
BE42.10-N-1012-10E | Operating pressure at coupling head for supply with burst compressed-air line of coupling head for brake | bar | 1,5 | - |
Test and adjustment values for service brake |
Number | Designation | Model 437.4 without code B89 | |
BE42.10-N-1001-10E | Pressure regulator shutoff pressure | bar | 17,8...18,8 |
BE42.10-N-1002-10E | Pressure regulator cut-in pressure | bar | 15,8 |
BE42.10-N-1003-10E | Time from pressure regulator cutting out until regeneration compressed-air reservoir has completely emptied | s | 20 |
BE42.10-N-1004-10E | Pneumatic pressure of service brake | bar | 8,3 |
BE42.10-N-1005-10E | Permissible pressure loss for operation of service brake with 3.5 bar (measuring period 3 minutes) | bar | 0,4 |
BE42.10-N-1006-10E | Operating pressure for service brake on rear axle (circuit 1) and front axle (circuit 2) | bar | 15,8...18,8 |
BE42.10-N-1007-10E | Operating pressure for trailer control, parking brake (circuit 3) | bar | 8,1...8,3 |
BE42.10-N-1008-10E | Operating pressure for transmission control, clutch operation (circuit 4) | bar | 8,1...8,3 |
BE42.10-N-1009-10E | Brake pressure at coupling head for brake with parking brake engaged | bar | 6,5...8,5 |
BE42.10-N-1010-10E | Brake pressure at coupling head for brake with parking brake in check position | bar | 0 |
BE42.10-N-1011-10E | Operating pressure at coupling head for compressed-air supply with burst compressed-air line of coupling head for brake | bar | - |
BE42.10-N-1012-10E | Operating pressure at coupling head for supply with burst compressed-air line of coupling head for brake | bar | 1,5 |