AR91.60-D-0611-05A | Deployment of airbag units when no deployment device is present | ||
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply.Model 901, 902, 903, 904, 905Nicht gültig für die Länder A, CH, D | |
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply.Model 415, 447, 636, 639, 900, 906, 909Nicht gültig für die Länder A, CH, D | |
Topical note | Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units | ||
| Ignition cable for firing airbag and seat belt tensioner units |
Use of self-fabricated ignition line
1 | Fabricate ignition line with a length of at least 10 m with pressure switch. |
2 | Connect 2-pin plug connection to squib of airbag unit to be scrapped. |
Maintain safe distance of at least 10 m from airbag unit to be scrapped. |
3 | Connect ignition line to battery. |
4 | Press both pushbuttons simultaneously. |
For airbag units with 2 squibs, both squibs must be deployed. To do so, repeat operation steps 2 to 4 after plugging the ignition line into the second squib. |