AR83.70-W-5808B | Remove/install housing segments | 16.1.98 |
MODEL 375.4 with BODY 375.840 with CODE (H60) Warm air heater "Eberspächer D1 LP"
MODEL 944 with BODY 944.899 with CODE (H60) Warm air heater "Eberspächer D1 LP"
MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H60) Warm air heater "Eberspächer D1 LP"
MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H60) Warm air auxiliary heater "Eberspächer" D1 LP
MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H60) Warm air heater "Eberspächer D1 LP"
W83.70-0082-06
1 Upper housing segment
2 Body-bound rivet
3 Outlet shroud
4 Lower housing segment
5 Gasket
| Remove/Install | ||
1 | Disconnect ground lead from battery | The ground lead must not be disconnected when the heater is in operation or during the run-on phase. | |
2 | Remove heater | Bodies 375.840, 944.899 | |
Body 942.899 | |||
Bodies 940.899, 972.899 | |||
3 | Remove outlet shroud (3) from housing segments (1, 4) | Press nose (arrow) of outlet shroud downward and remove outlet shroud. | |
4 | Remove expansion rivet (2) | Punch through expansion rivet drift (arrow A) and remove expansion rivet. Installation: Use new expansion rivet. | |
5 | Install in the reverse order | ||
Danger! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
6 | Check function of stationary heater |