ar8350t5090ca

Remove/install air conditioning dehydrator (roof equipment)

ประเภท ar · หัวข้อ 83.50 · เวอร์ชัน 0101 · 2019-06-18

ใช้กับ: Model NMB613.367 with code HKG (Konvekta ACX 623 air conditioning with roof heater)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.50 Rear air-conditioning — ซีรีส์ 613 (รุ่น 367)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.32 Housing/heat exchanger/evaporator/filter — ซีรีส์ 613 (รุ่น 367)

AR83.50-T-5090CA

Remove/install air conditioning dehydrator (roof equipment)

06.06.2019

Model

NMB613.367

with code HKG (Konvekta ACX 623 air conditioning with roof heater)

Remove/install air conditioning dehydrator (roof equipment)

1

Filter drier

2

Clip

3

Plug

4

Threaded connection

5

Filling valve

6

Electrical shutoff valve

T83.50-0070-11

Remove/install

Danger

Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area.

AS65.00-Z-0002-01A

Danger

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Topical note

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

1

Remove cover from filter drier (1)

AR83.50-T-5000-01C

2

Remove plug (3) and screw in manually operated shutoff valve completely

The manually operated shutoff valve is located below the plug (3). When the A/C is switched off, the electrical shutoff valve (6) is responsible for the function of the second manually operated shutoff valve.

3

Empty closed-off circuit of filter drier (1) via filling valve (5) using A/C suction and recycling equipment

Pay attention to the operating instructions of the A/C suction and recycling equipment.

Installation: Evacuate closed-off circuit of filter drier (1) via filling valve (5) using A/C suction and recycling equipment for at least 10 minutes and check for leaktightness.

4

Take off clamp (2)

5

Detach threaded connections (4) from filter drier (1)

Compressor oils (specification 362.0)

BB00.40-P-0362-00A

Installation: Use new sealing rings. Coat sealing rings with compressor oil before installation.

Refrigerant line to filter drier

*BA83.50-N-1002-01F

Warning

Risk of injury caused by damaged assemblies filled with refrigerant

Wear protective clothing, safety gloves and safety glasses.

AS86.61-Z-0001-01A

6

Detach filter drier (1)

If necessary, detach the refrigerant line between the filter drier (1) and the manually operated shutoff valve.

Installation: Check packaging of filter drier (1) for damage. Discard filter driers (1) with damaged packaging.
The filter drier (1) must be installed immediately after opening the packaging.
Observe direction of flow of filter drier (1).

7

Install in the reverse order

8

Check refrigerant level of air conditioning system

AP83.30-T-8312CA

9

Perform function test

Air conditioning system - function check

AP83.00-T-8352CA

Rear air conditioning

Number

Designation

MODEL 613.367 with CODE HKG

BA83.50-N-1002-01F

Refrigerant line to filter drier

Nm

44

เอกสารที่อ้างถึง