AR83.30-P-5550P | Check evaporator for leaks | 28.8.08 |
MODEL 203 with CODE (580) Automatic air conditioning
MODEL 203 with CODE (581) Comfort automatic air conditioning
P83.30-3445-05
1 Test adapter
2 Sealing ring
3 Retaining plate
4 Evaporator low pressure connection
5 Evaporator high pressure connection
6 Sealing ring
Checking | |||
Danger! | Risk of injury caused by moving parts that can pinch, crush or, in extreme cases even sever extremities. | Always remove ignition key when working on windshield wiper mechanism. | |
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling R134a refrigerant | All models with R134a refrigerant | |
1 | Remove expansion valve | ||
2 | Install test adapter (1) and adapter hose | Test adapter depends on diameter of pipe at air conditioner housing. | |
Install test adapter (1) in place of expansion valve with new sealing rings | |||
| |||
Test adapter | |||
Adapter | |||
Adapter hose | |||
Air conditioner pressure and leak tester (mobile) gotis://E_83_06.0 | |||
3 | Connect testing unit to test adapter (1) | ||
4 | Check evaporator for leaks | Fill system with a system pressure of | |
Temperature changes during the pressure test can cause pressure fluctuations, e.g. due to weather changes, overnight, cooling down of engine compartment. Make sure the ambient conditions remain constant. | |||
If faults are found: | |||
Remove/install evaporator | |||
5 | Disconnect testing unit from test adapter (1) | ||
6 | Remove test adapter (1) and adapter hose | Test adapter depends on diameter of pipe at air conditioner housing. | |
Test adapter | |||
Adapter | |||
Adapter hose | |||
7 | Install expansion valve | Install expansion valve with new sealing rings (2, 6). Coat thread and sealing rings (2, 6) with compressor oil. |
Air conditioning
463 589 01 63 00
Adapter hose
Adapter
Test adapter
140 589 51 63 00
140 589 51 63 01