ar8330p5540m

Removing and installing evaporator

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0104 · 2010-07-13

ใช้กับ: MODELS 215, 220

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 215 · ซีรีส์ 220

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.32 Housing/heat exchanger/evaporator/filter — ซีรีส์ 215 · ซีรีส์ 220

AR83.30-P-5540M

Removing and installing evaporator

12.7.10

MODELS 215, 220

Removing and installing evaporator

P83.30-1074-06

1 Evaporator housing

2 Clamp

3 Clip

4 Stepper motors, connection

Removing and installing evaporator

P83.30-1078-06

1 Evaporator housing

4 Stepper motors, connection

5 Stepper motors, connection

6 Clip

Removing and installing evaporator

P83.30-1082-06

7 Clip

8 Air distributor, upper section

9 Evaporator

Removing and installing evaporator

P83.30-1085-04

10 Screws

11 Expansion valve

Removing, installing

Danger!

Risk of explosion through welding or soldering operations on closed air conditioning system. Risk of poisoning through inhaling overheated refrigerant vapors. Risk of injury through skin and eye contact with fluid coolant

Do not carry out welding operations on closed air conditioning system or around it. Smoking and naked flame are forbidden. Wear protective glasses and protective gloves, work only in well ventilated areas. Only carry out repair operations on air conditioning circuit with system drained.

AS83.00-Z-0001-01A

Procedure with damaged or leaking air conditioning system

AH83.30-N-0004-01A

Protect air conditioning circuit and components from dampness when carrying out repair operations

AH83.30-N-0005-01A

Notes for handling refrigerant R134a

AH83.30-N-0003-01A

1

Drain air conditioning system (recycling), purge, fill, check for leaks

When evacuating refrigerant, the quantity of compressor oil evacuated must be added again to refrigerant circuit when refilling air conditioning (new oil)

2

Remove evaporator housing (1)

AR83.30-P-5200M

3

Remove heat exchanger

AR83.25-P-1100M

4

Detach stepper motors connections (4)

5

Detach 2 clamps (2)

6

Detach 4 clips (3)

7

Detach stepper motors connections (5)

8

Detach 7 clips (6)

9

Detach 7 clips (7)

10

Remove air distributor, upper section (8)

11

Detach evaporator core (9)

Clean air distributor, lower section

Installation: Note oil top-up quantity when replacing evaporator

*BF83.55-P-1004-01A

12

Unscrew screws (10)

Installation: Tighten screws alternately to avoid jamming

*BA83.30-P-1002-01A

13

Detach expansion valve (11)

Close off openings (parts kit),
replace O-rings (4) (moisten with compressor oil)

14

Replace fluid reservoir

AR83.30-P-6520M

15

Install in the reverse order

Air conditioning

Number

Designation

Model
215

Model
220

BA83.30-P-1002-01A

Screw, expansion valve

Nm

10

10

A/C compressor

Number

Designation

A/C compressor
7SE16
in model 215

A/C compressor
7SE16
in model 220

BF83.55-P-1004-01A

Additional oil quantity when replacing evaporator

Compressor oil

cm3

40

40

Specifications for service products

Sheet

BB00.40-P-0362-00A

BB00.40-P-0362-00A

เอกสารที่อ้างถึง