ar8325p1100m

Remove and install heat exchanger

ประเภท ar · หัวข้อ 83.25 · เวอร์ชัน 0104 · 2004-10-21

ใช้กับ: MODELS 215, 220

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.25 Automatic heater — ซีรีส์ 215 · ซีรีส์ 220

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.32 Housing/heat exchanger/evaporator/filter — ซีรีส์ 215 · ซีรีส์ 220

AR83.25-P-1100M

Remove and install heat exchanger

29.10.97

MODELS 215, 220

Remove and install heat exchanger

P83.25-0452-06

1 A/C housing

2 Screw

3 Cover

4 Clamp

Remove and install heat exchanger

P83.25-0451-06

5 Retaining clamp

6 Screw

7 Screw

8 Heat exchanger

9 Insert fork

10 Screw

c Heating water flow pipe

d Heating water return pipe

Remove/install

Danger!

Risk of injury to skin and eyes from scalding with hot coolant which splashes out. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles.

Wear protective gloves, protective clothing and eye protection.

AS20.00-Z-0001-01A

Danger!

Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant.

Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged.

AS83.00-Z-0001-01A

Conduct if air conditioning system is damaged or leaking

AH83.30-N-0004-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

All models fitted with air conditioning

AH83.30-N-0005-01A

Notes on handling refrigerant R134a

All models with R134a refrigerant

AH83.30-N-0003-01A

1

Drain air conditioning (recycle)

Replenish extracted quantity of compressor oil in the refrigerant circuit (fresh oil) when filling the air conditioning system.
Installation: Evacuate air conditioning system, fill, inspect for leaks.

Before filling the air conditioning system:

Replace receiver/drier

AR83.30-P-6520M

2

Remove AC housing

AR83.30-P-5200M

3

Unclip clamps (4)

4

Unscrew screws (2)

5

Take off cover (3)

6

Detach retaining clamps (5) on heating water flow pipe

7

Remove screws (6) of heating water flow pipe's bracket

8

Remove screws (7) of heating water flow pipe's guide

9

Pull out heat exchanger (8) with the heating water pipes

Clean heater housing from inside, if necessary remove escaping coolant.

10

Detach socket yoke (9), remove heating water flow pipe (c)

Fit new O-rings and replace socket yoke.

11

Remove bracket screw (10) and detach heating water flow pipe (d)

Fit new O-rings.

12

Install in the reverse order