ar8330p5520t

Remove/install expansion valve

ประเภท ar · หัวข้อ 83.30 · เวอร์ชัน 0104 · 2011-11-21

ใช้กับ: MODEL 211.0 /2 /6

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 3 Body › 83 Climate control › 83.30 Air conditioning — ซีรีส์ 211 (รุ่น 0**, 2**, 6**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.13 Line/hose/valve — ซีรีส์ 211 (รุ่น 0**, 2**, 6**)

AR83.30-P-5520T

Remove/install expansion valve

15.11.11

MODEL 211.0 /2 /6

Remove/install expansion valve

P83.30-3606-09

1 Expansion valve

2 Suction pipe

3 Pressure line

7 Suction pipe

8 Pressure line

4 Nut

5 Bolts

6 Retaining plate

Removing

Danger!

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling R134a refrigerant

AH83.30-N-0003-01A

1

Drain air conditioning (recycle)

Note quantity of extracted compressor oil.

Air conditioning draining, evacuating and charging equipment for refrigerant R134a

Air conditioner service unit R134a

gotis://E_83_05.0

2

Remove wiper system

AR82.30-P-6400T

3

Unscrew nut (4)

4

Detach suction line (2) and pressure line (3) from expansion valve (1)

Seal openings of intake line (2) and pressure line (3) to prevent dirt or moisture from entering.

Set of plugs for air conditioning system

5

Remove screws/bolts (5) and remove expansion valve (1)

Seal openings of suction line (7) and pressure line (8) to prevent dirt or moisture from entering.

Set of plugs for air conditioning system

Install

6

Replace sealing rings of suction line (7) and pressure line (8) and moisten thread of screw/bolt (5) with compressor oil

7

Screw screw/bolt (5) into retaining plate (6), pull retaining plate (6) forward and counterhold with a suitable screwdriver

8

Remove screw/bolt (5) from retaining plate (6)

9

Position expansion valve (1) and screw in screws/bolts (5)

Tighten screws (5) alternately to prevent canting.

*BA83.30-P-1002-01A

10

Install suction line (2) and pressure line (3) at expansion valve (1) and screw in nut (4)

Suction line (2) and pressure line (3) must not rest against body, otherwise the suction line (2) or pressure line (3) may be damaged.

Replace sealing ring and moisten thread with compressor oil.

*BA83.30-P-1001-01A

11

Install wiper system

AR82.30-P-6400T

12

Replace fluid reservoir

AR83.30-P-6520T

13

Evacuate air conditioning system, replenish and check for leaks

Too much or too little compressor oil can damage the refrigerant compressor.

Air conditioning draining, evacuating and charging equipment for refrigerant R134a

Air conditioner service unit R134a

gotis://E_83_05.0

Add noted quantity of compressor oil (new compressor oil) to air conditioning when filling.

Air conditioning system leak detector
gotis://E_83_04.0

Air conditioning

Number

Designation

Model
211

BA83.30-P-1001-01A

Nut on expansion valve

Nm

10

BA83.30-P-1002-01A

Expansion valve bolt

Nm

8

เอกสารที่อ้างถึง