Shown on model 907 |
1 | Underfloor paneling, left |
2 | Underfloor paneling, right |
D61.30-0001-06
Danger | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.Typ 910 mit Motor 780.703 | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
| Remove/install | ||
1 | Raise vehicle. | ||
Topical note | Special instructions for lifting and supporting vehicle | ||
2 | Remove left underfloor paneling (1). | ||
3 | Remove right underfloor paneling (2). | ||
4 | Install in the reverse order. |