Danger ! | Risk of injury caused by burns to skin and eyes. Risk of poisoning caused by inhaling fumes when working with heat-shrinkable tubing. | Work in well ventilated rooms only. Wear safety glasses with side protection and protective gloves. | |
Danger ! | Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
| Notes on battery | ||
| Assessment of damage in wiring harnesses | ||
| Notes on repair and extension of cable sets | ||
1 | Disconnect ground line from battery | ||
2 | Determine repair type for cable and cable sets | ||
3.1 | Repair/extend cables | Line cross-section up to 4 mm2 | |
Electric hot-air blower for plastics | |||
Terminal block for cable cross section up to 1.5 mm2 | |||
Terminal block for cable cross section up to 2.5 mm2 | |||
Terminal block for cable cross section up to 4.0 mm2 | |||
3.2 | Repair/extend cables | Line cross-section 10 mm2 and 16 mm2 | |
Electric hot-air blower for plastics | |||
Terminal block for cable cross-sections of 10 mm2 to 16 mm2 | |||
Brown electrical line 10 mm2 with receptacle, without insulating tubing, length 3000 mm | |||
Brown electrical line 10 mm2 with receptacle, with insulating tubing, length 8500 mm | |||
Red electrical line 10 mm2 with receptacle, without insulating tubing, length 3000 mm | |||
Red electrical line 10 mm2 with receptacle, with insulating tubing, length 8500 mm | |||
Brown electrical line 16 mm2 with receptacle, without insulating tubing, length 2500 mm | |||
Brown electrical line 16 mm2 with receptacle, with insulating tubing, length 6500 mm | |||
Red electrical line 16 mm2 with receptacle, without insulating tubing, length 2500 mm | |||
Red electrical line 16 mm2 with receptacle, with insulating tubing, length 6500 mm | |||
3.3 | Repair/extend cables | Line cross section larger than 16 mm2 | |
No repair possible. | |||
4 | Connect ground lead to battery | ||
5 | Check electrical system for proper operation |
Repair materials |
Number | Designation | Order number |
BR00.45-Z-1001-12A | Terminal block for cable cross section up to 1.5 mm2 | A 001 546 86 41 |
BR00.45-Z-1002-12A | Terminal block for cable cross section up to 2.5 mm2 | A 001 546 96 41 |
BR00.45-Z-1003-12A | Terminal block for cable cross section up to 4.0 mm2 | A 001 546 97 41 |
BR00.45-Z-1004-12A | Terminal block for cable cross sections of 10 mm2 to 16 mm2 | A 051 545 07 28 |
BR00.45-Z-1005-12A | Brown electrical line 10 mm2 with receptacle, without insulating tubing, length 3000 mm | A 000 540 75 27 |
BR00.45-Z-1006-12A | Brown electrical line 10 mm2 with receptacle, with insulating tubing, length 8500 mm | A 000 540 76 27 |
BR00.45-Z-1007-12A | Red electrical line 10 mm2 with receptacle, without insulating tubing, length 3000 mm | A 000 540 77 27 |
BR00.45-Z-1008-12A | Red electrical line 10 mm2 with receptacle, with insulating tubing, length 8500 mm | A 000 540 78 27 |
BR00.45-Z-1009-12A | Brown electrical line 16 mm2 with receptacle, without insulating tubing, length 2500 mm | A 000 540 67 27 |
BR00.45-Z-1010-12A | Brown electrical line 16 mm2 with receptacle, with insulating tubing, length 6500 mm | A 000 540 68 27 |
BR00.45-Z-1011-12A | Red electrical line 16 mm2 with receptacle, without insulating tubing, length 2500 mm | A 000 540 69 27 |
BR00.45-Z-1012-12A | Red electrical line 16 mm2 with receptacle, with insulating tubing, length 6500 mm | A 000 540 70 27 |