Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove | ||
1 | Remove battery to be charged. | Remove on-board electrical system battery | |
Remove on-board electrical system battery Model 910 | |||
Remove the auxiliary battery Model 907, 910 | |||
Remove auxiliary battery in engine compartment Model 907 | |||
Remove additional battery for emergency shift park pawl Model 907 | |||
| Check | ||
2 | Check condition of battery. | ||
Charging | |||
3 | Connect positive terminal of charger to positive terminal of the battery. | ||
| 000 588 00 81 00 Charger | ||
4 | Connect ground terminal of charger to negative terminal of battery. | ||
5 | Charge battery. | Normal charging: Charging current up to max. 10 % of battery capacity, e.g. max. 6.0 A charging current for a 60 Ah battery. | |
6 | Disconnect ground clamp of charger from battery. | ||
7 | Disconnect positive terminal of charger from battery. | ||
| Install | ||
8 | Install charged battery. | Install on-board electrical system battery | |
Install on-board electrical system battery Model 910 | |||
Install additional battery Model 907, 910 | |||
Install auxiliary battery in engine compartment Model 907 | |||
Install additional battery for emergency shift park pawl Model 907 |