ar5410d1130ts

Charge battery

ประเภท ar · หัวข้อ 54.10 · เวอร์ชัน 0101 · 2020-01-20

ใช้กับ: Model 907, 910

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 54 Electrical system, equipment and instruments › 54.10 Battery, power supply, voltage converter — ซีรีส์ 907 · ซีรีส์ 910

EinPAS 25 On-board/network/multifunction › 25.20 On-board electrical system › 25.20.20 Battery — ซีรีส์ 907 · ซีรีส์ 910

AR54.10-D-1130TS

Charge battery

13.01.2020

Model

907, 910

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

Remove

1

Remove battery to be charged.

Remove on-board electrical system battery
Model 907

AR54.10-D-0009TSR

Remove on-board electrical system battery Model 910

AR54.10-D-0009TSF

Remove the auxiliary battery Model 907, 910
with code E2I (Auxiliary battery for retrofitted consumers, interior)

AR54.10-D-0007TS

Remove auxiliary battery in engine compartment Model 907
with code E2M (Auxiliary battery for retrofit consumers, engine compartment)

AR54.10-D-0024TS

Remove additional battery for emergency shift park pawl Model 907
with code G42 (7G-TRONIC PLUS)
Model 907
with code G43 (9G-TRONIC)

AR54.10-D-0120TSR

Check

2

Check condition of battery.

AR54.10-D-1129TS

Charging

3

Connect positive terminal of charger to positive terminal of the battery.

000 588 00 81 00 Charger

WS54.00-P-0037B

4

Connect ground terminal of charger to negative terminal of battery.

5

Charge battery.

Normal charging: Charging current up to max. 10 % of battery capacity, e.g. max. 6.0 A charging current for a 60 Ah battery.
Rapid charging: Charging current from 10 % to max. 50 % of battery capacity for 30 min, e.g. max. 30 A charging current for a 60 Ah battery.
Follow the operating instructions for the charger.

6

Disconnect ground clamp of charger from battery.

7

Disconnect positive terminal of charger from battery.

Install

8

Install charged battery.

Install on-board electrical system battery
Model 907

AR54.10-D-0009TSR

Install on-board electrical system battery Model 910

AR54.10-D-0009TSF

Install additional battery Model 907, 910
with code E2I (Auxiliary battery for retrofitted consumers, interior)

AR54.10-D-0007TS

Install auxiliary battery in engine compartment Model 907
with code E2M (Auxiliary battery for retrofit consumers, engine compartment)

AR54.10-D-0024TS

Install additional battery for emergency shift park pawl Model 907
with code G42 (7G-TRONIC PLUS)
Model 907
with code G43 (9G-TRONIC)

AR54.10-D-0120TSR