1 | Additional battery |
2 | Cover |
3 | Nut |
4 | Battery clamp |
5 | Bolts |
6 | Bracket |
D54.10-1211-12
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Disconnect ground line from auxiliary battery (1) |
| |
2 | Remove cover (2) | ||
3 | Loosen nut (3) and remove battery clamp (4) from positive pole of auxiliary battery (1) | Nut, battery clamp to negative pole/positive pole of on-board electrical system battery/auxiliary battery | |
4 | Unscrew screws (5) and remove holder (6) | ||
5 | Remove auxiliary battery (1) from battery carrier | ||
6 | Install in the reverse order |