1 | Electrical connectors |
2 | Fuel line |
5 | Bracket |
6 | Locking ring |
7 | Cutouts |
8 | Fuel pump (FP) |
10 | Catch |
D47.20-A002-06
A | Lock incorrect |
B | Lock correct |
D47.20-A011-75
Danger | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove fuel tank. | ||
2 | Release and disconnect electrical connections (1). | ||
3 | Disconnect fuel line (2). | ||
| |||
Seal fuel line (2). | |||
Commercially available tools | |||
Record plug | |||
4 | Remove holder (5). | Installation: Check bracket (5) for damage. | |
If damage is present: | |||
| |||
Install new bracket(5). | |||
| Clean | ||
5 | Clean area around locking ring (6) at fuel pump (8) and fuel tank. | Assembly cleaner | |
6 | Release locking ring (6). | To do this, position claw wrench on cutouts (7) and turn locking ring (6) counterclockwise. | |
Installation: Ensure locking ring (6) is correctly locked (picture B). | |||
WIS Service Media | |||
Claw-type wrench | |||
7 | Remove fuel pump (8). | Installation: | |
Fill level sensor is fastened to the fuel pump (8). | |||
Installation: Replace sealing ring. | |||
| Clean | ||
8 | Clean sealing surfaces at fuel pump (8) and fuel tank. | Use a lint-free rag. | |
9 | Install in the reverse order. |
001 589 00 07 00
Claw-type wrench
129 589 00 91 00
Record plug