ar4330w0045wr

Remove/install return coolant hose on retarder

ประเภท ar · หัวข้อ 43.30 · เวอร์ชัน 0103 · 2017-04-04

ใช้กับ: Model 963, 964 with code B3H (Water-type secondary retarder)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 43 Brakes - pneumatic system and auxiliary brakes › 43.30 Retarder (hydraulic) — ซีรีส์ 963 · ซีรีส์ 964

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.21 Retarder › 21.21.13 Line/hose/valve — ซีรีส์ 963 · ซีรีส์ 964

AR43.30-W-0045WR

Remove/install return coolant hose on retarder

15.03.2017

Model

963, 964

with code B3H (Water-type secondary retarder)

Remove/install return coolant hose on retarder

Shown on connection fitting with magnet

1

Connection fitting with magnet

2

Clip

3

Coolant hose

4

Clip

5

Coolant line

W43.30-1698-06

Danger

Risk of death to implant wearers from working on retarder

As a safe distance from the retarder, a minimum distance of 100 cm is to be maintained between the retarder and the body parts of the affected person for people with implants.

AS43.30-Z-0002-01A

Warning

Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.

Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers.
Wear protective gloves, protective clothing and safety glasses.

AS20.00-Z-0001-01A

Topical note

Notes on coolant

AH20.00-N-2080-01A

Topical note

Notes on influence of retarder on coolant/coolant sludging

AH43.30-N-0003-01WR

Topical note

Notes on avoiding damage through contamination and foreign objects

AH00.00-N-5000-01H

Remove/install

1.1

Remove connection fitting with magnet (1) on retarder

With magnet

AR43.30-W-0059WR

1.2

Remove coolant connection return flow from retarder

Without magnet

AR43.30-W-0041WR

2

Detach clamps (2, 4) from coolant hose (3)


AR20.20-W-7470-01H

Pliers

*470589013700

3

Remove coolant hose (3)

Installation: Attach the clamps (2, 4) to the coolant hose (3). Clean connections for coolant hose (3).

4

Install in the reverse order

Remove/install return coolant hose on retarder

470 589 01 37 00

Pliers

เอกสารที่อ้างถึง