AR27.60-D-1155A | Check regulator pressure | 12.1.10 |
TRANSMISSION 722.330 in MODEL 901.3, 902.3, 903.3 with ENGINE 601.943
TRANSMISSION 722.375 in MODEL 901.4, 902.4, 903.4, 904.4 with ENGINE 602.980
TRANSMISSION 722.376 in MODEL 901.06, 902.0, 903.0, 904.0 with ENGINE 111.979
TRANSMISSION 722.337 in MODEL 903.312 /362 with ENGINE 601.943 with CODE (Z22) Post freight delivery service
TRANSMISSION 722.332 in MODEL 903.462 /463 with ENGINE 602.980 with CODE (ZB2) FedEx package
D27.10-0011-06
4 Banjo bolt
5 Sealing ring
7 Measuring instrument pressure line
R Test connection for regulator pressure
(measuring range up to 10 bar).
| Check | ||
The regulator pressure acts on the command valves and actuates the upshifts. The regulator pressure is regulated by the centrifugal governor. The pressure level varies depending on the centrifugal force, i.e., the pressure rises and falls depending on the vehicle speed. | |||
1 | Check vacuum control. | ||
2 | Heat transmission up to operating temperature. | ||
3 | Correct oil level in transmission | ||
4 | Connect test equipment for regulator pressure. | Measuring range up to 10 bar. Remove screw plug (R) with sealing ring (5) for test connection for regulator pressure. Connect pressure line (7) of test equipment with banjo bolt (4) and sealing rings (5) to test connection modulating pressure. Replace sealing ring. | |
| |||
| Measure with pointer instrument | ||
5 | On the roller dynamometer drive at the speeds specified in the tables and read off pressure values. | When fastening the test equipment in the cab, the difference in height from the test equipment to the transmission means that 0.1 bar for each meter must be added to the pressure value readings. If no regulator pressure is displayed or if the pressure values deviate from the values specified in the tables, the centrifugal governor must be cleaned or replaced. | |
Remove/install centrifugal governor | |||
6 | Disconnect measuring instrument in reverse order. | |
Housing
Number | Designation | Transmission 722.330/332 | ||
BA27.40-N-1002-01B | Screw plug for measuring points for modulating pressure, control pressure and working pressure | Nm | 13 | |
123 589 04 21 00
Tester