Gear set adjustment values
Number | Designation | Transmission 711.612/613 | ||
BE26.50-N-1003-01D | Axial play between countershaft and tensioning device | 0 (-0.06/+0.02) | ||
Transmission housing
Number | Designation | Transmission | |
BA26.40-N-1005-01A | Bolt, bearing cap to transmission housing | Nm | 21 |
711 589 02 31 00
Tensioning device
Repair materials
Number | Designation | Order number |
BR00.45-Z-1012-01A | Omnifit FD 3041 sealant | A 002 989 47 20 10 |
D26.50-0066-01
D26.50-0065-01
1 Remove bearing cap (2).
2 Remove setting ring (3).
D26.00-0051-01
3 Fit tensioning device with thrust piece on to tapered roller bearing outer race.
4 Bolt tensioning device to transmission housing with 2 bolts.
5 Tighten bolt to 10 Nm. When doing so, turn drive shaft so that the tapered roller bearings can settle.
D26.50-0068-01
6 Measure dimension "A" from edge of sealing surface to tapered roller bearing outer race using a depth gauge.
D26.50-0069-01
7 Select appropriate setting ring (see table for specified dimension).
Aim for countershaft axial play of 0 mm.
Example: Dimension "A" measurement = 2.7 mm, corresponds to a setting ring thickness of 2.7 mm.
Setting rings are available in thicknesses from 2.2 mm to 2.95 mm, in 0.05 mm graduations.
D26.50-0066-01
8 Insert required setting ring.
D26.50-0070-01
D26.50-0065-01
9 Coat bearing cap (2) and bolts (1) with Omnifit sealant (see table).
Ensure no sealant enters the oil duct (arrow).
10 Install bearing cap (2).
Pay attention to tightening torque.