ar2650d200102b

Adjust axial play of countershaft

ประเภท ar · หัวข้อ 26.50 · เวอร์ชัน 0114 · 2010-01-19

ใช้กับ: TRANSMISSION 711.612 /613

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 26 Manual transmission › 26.50 Gear assembly, shafts, differential

EinPAS 17 Drivetrain/axle › 17.20 Transmission › 17.20.50 Shaft/gear/synchronization

ใช้กับเครื่องยนต์/เกียร์ด้วย: 711 612, 711 613

AR26.50-D-2001-02B

Adjust axial play of countershaft

Gear set adjustment values

Number

Designation

Transmission 711.612/613

BE26.50-N-1003-01D

Axial play between countershaft and tensioning device

0 (-0.06/+0.02)

Transmission housing

Number

Designation

Transmission
711.612/613

BA26.40-N-1005-01A

Bolt, bearing cap to transmission housing

Nm

21

Adjust axial play of countershaft

711 589 02 31 00

Tensioning device

Repair materials

Number

Designation

Order number

BR00.45-Z-1012-01A

Omnifit FD 3041 sealant

A 002 989 47 20 10

Adjust axial play of countershaft
Adjust axial play of countershaft

D26.50-0066-01

D26.50-0065-01

1 Remove bearing cap (2).

2 Remove setting ring (3).

Adjust axial play of countershaft

D26.00-0051-01

3 Fit tensioning device with thrust piece on to tapered roller bearing outer race.

4 Bolt tensioning device to transmission housing with 2 bolts.

5 Tighten bolt to 10 Nm. When doing so, turn drive shaft so that the tapered roller bearings can settle.

Adjust axial play of countershaft

D26.50-0068-01

6 Measure dimension "A" from edge of sealing surface to tapered roller bearing outer race using a depth gauge.

Adjust axial play of countershaft

D26.50-0069-01

7 Select appropriate setting ring (see table for specified dimension).

Aim for countershaft axial play of 0 mm.

Example: Dimension "A" measurement = 2.7 mm, corresponds to a setting ring thickness of 2.7 mm.

Setting rings are available in thicknesses from 2.2 mm to 2.95 mm, in 0.05 mm graduations.

Adjust axial play of countershaft

D26.50-0066-01

8 Insert required setting ring.

Adjust axial play of countershaft
Adjust axial play of countershaft

D26.50-0070-01

D26.50-0065-01

9 Coat bearing cap (2) and bolts (1) with Omnifit sealant (see table).

Ensure no sealant enters the oil duct (arrow).

10 Install bearing cap (2).

Pay attention to tightening torque.