1 | Electrical connector |
2 | Electrical connector |
3 | Exhaust aftertreatment unit |
A60 | Exhaust aftertreatment (ACM) control unit |
W14.40-1529-06
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on safety-relevant components | |||
| Remove/install | ||
1 | Connect diagnostic system, start XENTRY and perform quick test. | Only when exhaust aftertreatment (ACM) control unit (A60) is replaced. | |
2.1 | Select "Control unit replacement" and follow the instructions. | When exhaust aftertreatment (ACM) control unit (A60) is replaced. | |
Control unit replacement is completely menu-assisted under: | |||
Installation: Follow instructions for "Control unit replacement". | |||
2.2 | Switch off ignition. | When exhaust aftertreatment (ACM) control unit (A60) is not replaced. | |
3 | Disconnect electrical connector (1) at aftertreatment control module (ACM) (A60). | ||
4 | Disconnect electrical connector (2) from exhaust gas aftertreatment control unit (ACM) (A60). | ||
5 | Remove exhaust gas aftertreatment control unit (ACM) (A60) from bracket. | Exhaust aftertreatment control unit to bracket | |
6 | Install in the reverse order | ||
7 | Link aftertreatment control module (ACM) (A60) and exhaust gas aftertreatment unit via VeDoc center. | Only if exhaust gas aftertreatment unit (3) will also be replaced in addition to aftertreatment control module (ACM) (A60). | |