ap1320t1350ca

Inspect condition of V-belt, re-tension

ประเภท ap · หัวข้อ 13.20 · เวอร์ชัน 0100 · 2005-07-12

ใช้กับ: ENGINE 457.941 in MODEL 613.368

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 1 Engine › 13 Air compressor, belt drives › 13.20 Belt drive, general — ซีรีส์ 613 (รุ่น 368)

EinPAS 15 Engine › 15.18 Belt drive › 15.18.30 Belt/belt pulley/clamping device/guide pulley — ซีรีส์ 613 (รุ่น 368)

ใช้กับเครื่องยนต์/เกียร์ด้วย: 457 941

AP13.20-T-1350CA

Inspect condition of V-belt, re-tension

15.5.02

ENGINE 457.941 in MODEL 613.368

Inspect condition of V-belt, re-tension

T13.20-0018-01

Shown on engine 457.941 with code HA4

A Alternator 1 drive

B Fan drive

C Drive for AC and water pump

D Alternator 2 drive

Inspect

1

Check V-belts for cracks, oiling, overheating and wear

If wear or damage is present, replace
V-belt.

- against separate order.

2

Check V-belt tension

Tension of V-belt not correct:

AP13.20-T-1350-02CA

Retensioning V-belt

AP13.20-T-1350-01CA

*BE13.21-N-1002-01D

*BE13.21-N-1003-01D

*BE13.21-N-1004-01D

*BE13.21-N-1005-01D

*BE13.21-N-1006-01D

*001589692100

Inspection and setting data of multi-belt drive

Number

Designation

Engine 457.941

Engine
457.941
with code HA4

BE13.21-N-1002-01D

Fan drive double V-belt tension

V-belt, new

Hz

57,6...59,1

-

N

1850...1950

-

V-belt, used

Hz

49,2...51,0

-

N

1350...1450

-

Minimum operating voltage

Hz

44,4

-

N

1100

-

BE13.21-N-1003-01D

Alternator 1 drive V-belt tension

V-belt, new

Hz

-

121,0...130,0

N

-

650...750

V-belt, used

Hz

-

94,8...106,0

N

-

400...500

Minimum operating voltage

Hz

-

88,7

N

-

350

BE13.21-N-1004-01D

AC drive and water pump
V-belt tension

V-belt, new

Hz

-

127,0...133,0

N

-

1150...1250

V-belt, used

Hz

-

103,0...109,0

N

-

750...850

Minimum operating voltage

Hz

-

95,7

N

-

650

BE13.21-N-1005-01D

Alternator 2 drive V-belt tension

V-belt, new

Hz

-

167,0...179,0

N

-

650...750

V-belt, used

Hz

-

131,0...146,0

N

-

400...500

Minimum operating voltage

Hz

-

123,0

N

-

350

BE13.21-N-1006-01D

Alternator 1 drive and water pump
V-belt tension

V-belt, new

Hz

122,0...127

-

N

1050...1150

-

V-belt, used

Hz

95,7...103

-

N

650...750

-

Minimum operating voltage

Hz

88,1

-

N

550

-

Inspect condition of V-belt, re-tension

001 589 69 21 00

Measuring instrument

เอกสารที่อ้างถึง