AN54.18-W-1001-02PR | Install battery cable bracket | ||
Danger! | Risk of death caused by working on permanent magnet retarder for groups of persons with implants. Risk of injury caused by burns that may occur due to contact with the hot rotor. | For persons with implants, a minimum distance of 30 cm between the permanent magnet retarder and the body parts of the affected person is to be maintained as a safe distance from the permanent magnet retarder. Do not touch hot or rotating parts. |
W54.18-1108-11
1 Mount new bracket (9) onto transmission.
The new bracket (9) is fastened with one bolt only to the transmission.
W54.18-1109-11
2 Mount bracket (3, 4) with battery cable (5, 6) to new bracket (9).
W54.18-1110-11
3 Remove cable tie (10) and remove spacer (11).
W54.18-1111-11
4 Route subharness (12) upwards.
5 Fasten subharness (12) with spacer (11) and cable tie (13) to top hole of bracket (14).
W54.18-1112-11
6 Fasten new bracket (15) with bolt (16) to bracket (14).
7 Fasten battery cable (5, 6) with new bracket (17) to bracket (15).
W43.40-1030-06
8 Mount connector (1) to transmission output speed rpm sensor (B57).
Only with code (GE1) Automatic gear control (AGS).
9 Mount connector (2) to speed sensor (B17).