ar2645d1001a

Remove/install switchover valve

Vrsta ar · tema 26.45 · različica 0101 · 2017-02-16

Velja za: Transmission 711 in model 906 with code N05 (Power take-off countershaft (2c) without flange) Transmission 711 in model 906 with code N07 (Power take-off countershaft (2b) with flange)

Ni na voljo v jeziku »sl«; prikazano v jeziku Angleščina.

Umestitev

Funkcijska skupina 2 Podvozje › 26 Mehanski menjalnik › 26.45 Dodatni pogon, gonilo prenosne gredi — Serija 906

EinPAS 17 pogonski sklop/prema › 17.20 menjalnik › 17.20.13 napeljava/gibka cev/ventil — Serija 906

Velja tudi za motorje/menjalnike: 711 ***

AR26.45-D-1001A

Remove/install switchover valve

16.02.2017

Transmission

711 in model 906

with code N05 (Power take-off countershaft (2c) without flange)

Transmission

711 in model 906

with code N07 (Power take-off countershaft (2b) with flange)

Remove/install switchover valve

1

Vacuum line

2

Switchover valve

3

Electrical connector

Pfeil

Release

D26.45-1023-05

Remove/install

1

Open engine hood

2

Remove vacuum line (1)

3

Unlock switchover valve (2) (arrow) and unclip

4

Release and disconnect electrical connection (3)

5

Remove switchover valve (2)

6

Install in the reverse order

Danger !

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear buttoned-up and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

7

Perform engine test run and check functioning of switchover valve (2)