AR91.40-P-0611-05RT | Firing removed emergency tensioning retractors when ignition device is not present | ||
Danger! | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | |
| Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units | ||
| Ignition cable for firing airbag and emergency tensioning retractor units | ||
| Notes on disposing of airbag and emergency tensioning retractor units | All models |
Application of shop-made ignition cables
1 Fabricate ignition cables at least 10 m long with a pressure switch at the end.
2 Plug the 2-pin plug connector into the corresponding emergency tensioning retractor unit.
3 Connect ignition cables to the battery.
4 Press both pressure switches simultaneously.
Keep a distance of 10 m for safety.
Связанные документы
- ah9160p061102p Указания по контролируемой активации блоков фронтальных / боковых подушек безопасности и натяжителей ремней безопасности
- as9100z000101a Опасность получения травмы при проведении работ по диагностике и ремонту подушекбезопасности или аварийных натяжителей ремней б
- os9100p000101a
- wf5850p916002a Провода зажигания для активации блоков подушек безопасности и натяжителей ремней безопасности